HomeMy WebLinkAbout Cabot Blvd. #11 - 11/5/1980lugMassachusetts Water Resources Commission / Division of Water Resources
vjkER WELL COMPLETION REPORT
WELL LOCATION
Address i;�hlli Rlz7s=1
City/Town
G.S. Quadrangle Map
Grid Location _
Owns(
-
CONSOLIDATED WELL
WELL USE
Domestic ❑ .Public ❑ Industrial
Type of Water -bearing Rock _ s�t^''a T1T
Other
Water -bearing Zones
1) From To :I
METHOD DRILLED
To
Rotary (type) 'X' Cable ❑
21 From
- To
3) From
Other
4) From To
CASING
Depth to Bedrock
� nu
Length -all, Diameter
WELL
,�-r <'Pl
UNCONSOLIDATED
Type
Water -bearing Materials
STATIC WATER LEVEL
'
fineo. medium❑ coarse
Feet below land surface
Sand:
Gravel: fine❑ medium❑ coarse❑ �
Date measured �-----
Screen:
GRAVEL PACK WELL
Slot# length __from__to__
Yes Cj No ❑
Split Screen (or 2nd screen)
Slot # _length__from__tc_ -j
WATER QUALITY TESTS MADE
. Chemical Biological Q
Depth To Bedrock _'
PUMP TEST
-
Drawdown feet after pumping___.
days hours at 100 GPM.
-
Recovery__ feet after hours.
How measured �------
LOG of FORMATIONS
COMMENTS: (on well or water)
- . . r_..... Tn
O
DRILLER
Firm 'A °' ;NJ ARTI�'STAN YLEI 1,
Address L1i'•'(1 "f �'�
Registration
I
5 ;gnat. re
10M 9-78-150519
THE COMMONWEALTH OF MASSACHUSETTS
Towu oflansfield
BOARD OF HEALTH
Edward J. Tartufo, Chairman
Francis A. Gasson Clerk
Karl D. Clemmey
Stanley Sohn, DVM
Louis Diamond
August 28, 1980
Date mintersil Inc.
11 Cabot Bivd,
Mansfield, Ma. 02048
Gentlemen:
The Board is in receipt of a copy of a Water Well Completion Report
from the. t+assachusetts Water Resources Commission, Division of Water
Resources.
At this time the Board requests a copy of the report of the water
results be sent to the Board in complete form showing the location
of the well.
The Board wishes to thank you at this time for taking this step in
view of the present water shortage. We suggest you place a sign
advising you are using well water.
Sincerely,
Edward J. Tartufo
Chairman
E JT/da b
l
11 Cabot Blvd., Mansfield, MA 02048 U.S.A.
Telephone: (617) 339-9341
TWX: (710) 346-1953
TELEX: 95.1340
October 22, 1980
Town of Mansfield
Board of Health
Mr. Edward J. Tartufo, Chairman.
Enclosed is the report requested by the Health Department of the
water results taken from the well which is located on the North
East side of Datel lntersil's property.
Sincerely,
Dave Ahern,
plant Engineer
DA/bcs
THE COMMONWEALTH OF MASSACHUSE TS
Mansfield
of �' 6 E g
BOARD OF HEALTH
November 3, 1980
Dave Ahern,
Plant Engineer
Dater Intersil
11 Cabot Blvd.
Mansfield, Na. 02011B
Ve: Well Water Results
Dear Mr. Ahern:
The Board is in receipt of the water resu-tts taken from the well which
is located on the Northeast side of ,your property.
Please be advised, as noted on the test report from Oliveira Laboratories,
notes that the water is not acceptable for drinking or domestic purposes.
Please advise the Board for what purposes you will be using this water.
Sincerely,
i
Edward J. Tar_Wfo,
Chairman
WT/dab
11 Cabot Blvd., Mansfield, MA 02048 U.S.A.
Telephone: (617) 339-9341
TWX: (710) 346-1953
TELEX: 95-1340
Edward J. Tartufo,
Chairman
Town of Mansfield
Board of Health
Mansfield, Mass. 02048
Dear Mr. Tartufo
November 5, 1980
In compliance with your letter dated November 3, 1980, please be
advised that we are presently using the well water for watering our
lawns.
In the near future we will also be using the water to cool our
equipment.
We are not and will not be using the water for drinking or domestic
purposes.
Sincerely yours,
Dave Ahern,
Plant Engineer
DA/bc s
THE COMMONWEALTH OF MASSACHUSETTS
nn
Film of Manfield
BOARD OF HEALTH
November 25, 1980
Dave Ahern,
Plant Engineer
Da.tel Intersil
11 Cabot Blvd.
Mansfield, Ma. 02018
Dear Mr. Ahern:
The Board is in receipt of your letter reaardinp your well water.
Please be advised, the Board does not see any problems with the
proposed use.
Sincerely,
Edward J. Tartufo,
Chairman
EJT/dab
The Standard Plate Count indicated the general bacterial population of the well at the time of collection
Coliform Group Bacteria:
Significance
The coliform group bacteria includes organisms found in the intestinal tracts of warm blooded animals, birds, decaying organic matter (hay,
leaves, wood, etc.), the top 2 to 3 feet of the soil, lakes, ponds, brooks, rivers, drainage and types of vegetation.
Because the organisms can cause some illness; because the presence of coliform organisms in the water suggests that other more harmful
organisms may be present, water containing one or more coliform group bacteria per 100 ml of sample should not be used for drinking or
nnnkino numoses unless boiled 5 minutes or isinfected by other means.
This bacteria is of animal origin (intestinal tract) and may be considered as closely associated with disease causing organisms. On, this. factor,,
none should be present.
Color — APC Units - Ground water ought to be practically free from color. For attractive water - color should not exceed 15 units.
Turbidity — NT Units - Recommended limit not to exceed 5 units.
Odor & Taste — For water to be of high quality, the water should be odor free and taste good.
pH — The pH value defines the concentration of free hydrogen ions in solution. Expressed on a scale extending from 0 or very acid to 14 or
very alkaline with 7.0 being neutral.
Specific Conductance — Conductivity is a good criterion for measuring the degree of mineralization and assessing the affect of diverse ions
on chemical equilibria.
Total Alkalinity — The alkalinity of this water represents its content of carbonates and bicarbonates.
Free Carbon Dioxide — Well water having a low pH and a Free CO, level in excess of 50. mg/I will be corrosive to iron, bronze, brass and
copper tubing and fittings.
Total Hardness — Standard not to exceed 50. mg/l. Waters having a hardness level of 50 to 100 are in the medium hardness range, over
100 very hard.
Calcium -- Calcium contributes to the total hardness of water. Appreciable amounts of calcium salts break down on heating and form scale
in boilers, pipes and cooking utensils.
Magnesium — Magnesium is a common constituent of natural water. Magnesium and calcium ions are principal contributors to water hard-
ness. Concentrations in excess of 125 mg/I can exert a catharticand. diuretic action.
Sodium — Recommended limit not to exceed 20 mg/l.
Potassium — Potassium concentrations in drinking water seldom exceed 20. mg/I.
Total Iron — Standard not to exceed 0.3 mg/I.
Manganese — Standard not to exceed 0.05 mg/I. The principal reason for limiting the concentration of manganese is to reduce esthetic and
_..__._..._,_.,__..._,_...,__.-._ _.... _
economic problems.
Silica — Silica content of natural water is most commonly in the 1 to 30 mg/I. Silica in water is undesirable because it forms difficult to
remove silica scales.
Sulfates — Standard not to exceed 250 mg/I.
Chloride — Standard not to exceed 250 mg/I.
Nitrogen — Ammonia is present in variable concentrations in many surface and ground waters. Its occurrence in ground water is generally a
result of natural reduction processes.
Nitrogen - Nitrite — Nitrite in water poses a health hazard, but fortunately seldom occurs in high concentrations. Waters with a nitrogen -
nitrite concentration over 1 mg/I should not be used for infant feeding.
Nitrogen - Nitrate — Standard not to exceed 10. mg/l. Nitrate, in high concentrations can and do cause methemoglobinemia or so-called
nitrate poisoning in infants. Water with 10 or more mg/I of nitrate is unsatisfactory and is not considered safe for drinking or cook-
ing. It is especially dangerous to children and should never be used in infant formulas.
Copper — Standard not to exceed 1.0 mg/I.
VICTOR OLIVEIRA, R.S., C.H.O.
OLIVEIRA LABORATORIES
FOOD - DAIRY PRODUCTS - WATER - WASTEWATER
CHEMICAL a BACTERIOLOGICAL ANALYSES
697-2650
OFFICE
1498 HIGH STREET
BRIDGEWATER, MASS. 02324
LABORATORY.
176 PLYMOUTH STREET
BRIDGEWATER, MASS. 02324
September 24, 1980
Datel - Intersil, Inc,
11 Cabot Boulevard
14ans£ield, Mass. 02048
Sources Well Water - Drilled Well - 2W feet deep - producing 100 gals./min.
Located on the Dotal - Intersil property - 11 Cabot ➢oulevard,
Mansfield, Mass,
Colifnrm Count
/700 ml @ 35 C 43
Membrane filter —
S.P.C./ml 300
@35C
Conductance
mg /liter
Sample collected by Mr. David Kiklis of Datel - Intersil, Inc. - 9/18/80.
Sample delivered. to laboratory by Mr. David Y.iklis - 9/18/80 at 2,10 P,tfl.
Bacteriologically, this well water Is presently of an unsatisfactory sanitary
standard and is unsuitable for drinking and domesti-c purposes.
Chemically, this well water is high in manganese content. All. other
chemicals tested meet the standards.-
Director