Loading...
HomeMy WebLinkAboutSmith & Nephew Emergency & Hazardous Contingency Plan - 10/6/2017Smith & Nephew, Inc. 130 Forbes Boulevard Mansfield, MA 02048 USA October 06, 2017 1-508-261-3600 1-800-544-2330 www.smith-nephew.com Mansfield Board of Health, Health Agent 6 Park Row Mansfield, MA 02048 (508) 261-7366 Re: Smith & Nephew's Emergency Action/Hazardous Waste Contingency Plan Dear Health Agent Amy Donavon-Palmer: c�p ri r 1! Cif �1 - Smith & Nephew is a generator of hazardous waste. The Massachusetts Department of Environmental Protection (MassDEP) hazardous waste regulations (in 310 CMR 30.341(1)(c)) require that we submit copies of our hazardous waste contingency plan to the agencies that may be called upon to respond in the event of an emergency, and to make arrangements with these agencies to provide assistance during such emergencies. As such, we have enclosed a copy of our facility's Contingency Plan for your review and use. The plan describes the assistance we would like you to provide in the event of an emergency at our facility. Please review the plan and let us know if you are capable of and willing to provide the services specified. Please acknowledge your assent by signing the enclosed letter and returning it to us. If you are incapable of or unwilling to provide the requested services, please contact me by phone so that we may discuss the issue further and resolve it. We greatly appreciate your assistance. Please don't hesitate to call me at (508) 261-3697 if you have questions, would like to discuss any information contained in the plan, or would like to arrange for a facility tour. I look forward to hearing from you soon. Sin cere , , r a ente Smith & Nephew HSE & Facilities Manager, denice.parente@smith-nephew.com Enclosure — Smith & Nephews Emergency Action/Hazardous Waste Contingency Plan ,-°,, wraith nephew EMERGENCY ACTION/HAZARDOUS WASTE CONTINGENCY PLAN Smith & Nephew, Inc. Mansfield Facility - Mansfield, Massachusetts Prepared For: Smith & Nephew, Inc. 130 Forbes Boulevard Mansfield, Massachusetts 02048 Prepared By: Denice Parente, HSE & Facilities Manager Smith & Nephew, Inc. Date: September 2017 r � Copy of ,. .i. mitl ne h w RECORD OF CHANGES EMERGENCY ACTION/IIAZARDOUS WASTE CONTINGENCY PLAN Revision Date of Person Maldng Sections Affected Level Revision Revision 1 1/26/00 Ed Martynowski Pg. 2 —Number of employees changes from 230 and deleted Evaporation waste, Pg. 3 — Generator status (SQG) added, Pg. 15 — Administrative corrections, Appendix B — Update locations of waste storage areas, Appendix C — Updated weekly audit log, Appendix D - Added EC and updated phone numbers, Appendix F — Updated evacuations plans 5 and 9, and Appendix G — Updated locations of fire extinguishers Appendix H - Added 2 May 2002 M. D'Eufemia Minor changes throughout the text, update appendices 3 4arch 2004 M. D'Eufemia Minor changes throughout the text, update appendices including evacuation route maps and assembly areas. Change plan name from Hazardous Waste Contingency to Emergency Action Plan. Hazardous Waste Contingency is not required since the facility is a small quantity generator of hazardous waste. 4 May 2005 D. Skarin Update to Appendix C due to organizational changes. Update to Appendix F to reflect current fire extinguisher locations. 5 November D. Parente Update the location of the new AED, the number of 2007 Employees and operating hours. 6 November D. Parente Minor changes throughout the text. 2008 Appendix A - H 7 Npril2009 D. Parente Update list of Hazardous waste locations 8 May 2009 D. Parente Updates to reflect SQG to LQG 9 June 2009 D. Parente Update Appendix D - Emergency Record Log smith e hew 10 August D. Parente Update Appendix D - Emergency Record Log, and 2009 Appendix G — Location of Fire Suppression 11 August D. Parente Update Appendix A — List and Location of Hazardous 2010 Waste Storage/Accumulation Areas Update Appendix B — Weekly Audit Log Update Appendix C — List of Emergency Coordinators Update Appendix D — Emergency Record Log Update Appendix E — Evacuation Route Maps Update Appendix F — Location of Fire Extinguishers Update Appendix G — Location of Fire Suppression Update Appendix H— Location of Spill Control Equipment Update Table 1 & 2 Hazardous & non -Hazardous Waste Update Section 5.0— change from 5 satellite accumulation areas to 9. Update Section 9.5 — change from 6 First -aid areas to 4 12 December D. Parente Update Appendix D - Emergency Record Log. Added 2010 Spill Requirements in section 7.2 13 December D. Parente Update section 7.2.6 on reporting spills 2010 14 November D. Parente Minor changes throughout the text, and update 2012 appendices. 15 November D. Parente Minor changes throughout the text and add the April 2013 Fire to the Emergency Record Log 16 January D. Parente Minor changes throughout the text and update fire 2015 suppression log 17 May 2017 D. Parente Minor changes throughout the text and update fie suppression log 18 July 2017 D. Parente Update emergency Log 19 eptember D. Parente Update Fires Suppression Log Appendix G add Fire 2017 Trace FM200 TABLE OF CONTENTS SECTION 1.0 PURPOSE ............ 2.0 SCOPE..... PAGE 3.0 LOCATION.....................................................................................................................................2 4.0 GENERAL FACILITY DESCRIPTION AND CHARACTERISTICS OF WASTES ................3 5.0 HAZARDOUS WASTE STORAGE AREAS...............................................................................4 6.0 RESPONSIBILITY, EMERGENCY COORDINATORS, AND CHAIN OF COMMAND ....... 5 7.0 EMERGENCY PREVENTION AND RESPONSE PROCEDURES..........................................8 7.1 Emergency Prevention.................................................................................... 8 7.2Incidental Spills.................................................................................................................10 7.3 All Other Spills of Wastes................................................................................................11 7.4 Small Fires........................................................................................................................12 7.5 Large Fires and Explosions...............................................................................................13 7.6 Medical Emergencies........................................................................................................14 7.7 Following Emergencies....................................................................................................15 8.0 EVACUATION PLAN ...................... ..................................................15 9.0 EMERGENCY RESPONSE EQUIPMENT, SIGNS, AND MARKINGS. 91 Communication Systems.................................................................. 9.2 Fire Control Equipment.................................................................... 9.3 Spill Control Equipment................................................................... 9.4 Personal Protective Equipment (PPE) .............................................. 9.5 First Aid Equipment.......................................................................... 9.6 Testing and Maintenance of Equipment ........................................... 17 0 9.7 Required Aisle Space 10.0 ARRANGEMENTS WITH LOCAL AUTHORITIES 11.0 NOTIFICATION REQUIREMENTS 12.0 PLAN AMENDMENTS APPENDICES ,-� smith ne hew ...............................................20 TABLE OF CONTENTS (CONTINUED) Appendix A List and Location of Hazardous Waste Storage/Accumulation Areas Appendix B Weekly Audit Log Appendix C List of Emergency Coordinators and Emergency Services Phone Numbers Appendix D Emergency Record Log Appendix E Outside Assembly Area & Evacuation Maps Appendix F Locations and Capabilities of Fire Extinguishers Appendix G Locations of CO2 Fire Suppression Systems Appendix H Locations of Spill Control Equipment Including PPE all smittAnephew Mansfield Facility —Emergency Action/Hazardous Waste Contingency Plan Rev. 16 Sentenrber 2017 Page 1 EMERGENCY ACTIONMAZARDOUS WASTE CONTINGENCY PLAN Smith & Nephew, Inc. - Mansfield Facility 1.0 PURPOSE In the event of an emergency, the Mansfield facility of Smith & Nephew will be prepared to protect the safety and health of its employees, neighbors, and the enviromnent. This Emergency Action/Hazardous Waste Contingency Plan follows the Occupational Safety & Health Administration (OSHA) requirements for emergency action plans (29 CFR 1910.38). The facility is classified as a large quantity generator (LQG) under the Massachusetts Department of Environmental Protection (MADEP) Hazardous Waste Regulations (310 CMR 30.351(1)). As a LQG, MADEP regulations require a written contingency plan; therefore, emergency procedure, prevention, and response requirements outlined in this plan also meet the requirements of 310 CMR 30.000. Further, Smith & Nephew Inc. Mansfield personnel shall not perform emergency response as defined in 29 CFR 1910.120. As such, the requirements of these regulations are not necessarily in this plan. Thus Emergency Action Plan has been prepared to protect personnel safety and minimize hazards to public health, safety, or welfare, or the environment, from fires, explosions, spills, or any unplanned sudden or non -sudden releases of hazardous materials to the air, soil, surface water, or ground water. This plan provides Smith & Nephew, Inc. Mansfield facility personnel and local authorities the necessary tools to carry out the provisions of this plan in the case of an emergency. 2.0 SCOPE This Emergency Action Plan applies to all Smith and Nephew Inc. employees. It provides a clear outline and procedure to communicate and take necessaty actions in response to potential or actual hazards that may be encountered at the Mansfield facility. This plan also provides the instruction and guidance to identify a hazard, locate equipment, and contact emergency professionals for assistance. In addition, this plan provides emergency professionals with the necessary information to respond to hazards, injuries, and illnesses that corild result from a fire, explosion spill, or release of hazardous waste or constituents of hazardous waste at the Mansfield facility. �% smith rtephew Mansfield Facility — Emergency ActiorA-Iazardous Waste Contingency Plan Rev. 16 September 2017 Page 2 Employees are trained to the provisions outlined in this plan and the plan is executed immediately in the event of a fire, explosion, spill, or release of hazardous waste or constituents of hazardous waste at the Mansfield facility that could threaten employee or public health, safety, or welfare, or the environment. This plan does not cancel or supersede any other Smith & Nephew procedures or instructions. This plan shall be kept current, and shall be revised and redistributed when information contained herein changes. 3.0 LOCATION A copy of this plan is available in the Human Resources office and the Health, Safety and Environment Office at the Mansfield facility, as appropriate. In addition, a copy has been submitted to the following agencies and businesses: Mansfield Fire Department, Fire Chief 10 Plymouth Street Mansfield, MA 02048 (508)261-7490 Mansfield Board of Health, Health Agent 6 Park Row Mansfield, MA 02048 (508) 261-7366 Mansfield Health Center 200 Copeland Drive Mansfield, MA 02048 (508) 339-4144 Mansfield Police Department, Police Chief 50 West Street Mansfield, MA 02048 (508)261-7300 Sturdy Memorial Hospital 211 Park Street Attleboro, MA 02703 (508) 222-5200 Mansfield Town Manager 6 Park Row Mansfield, MA 02048 (508)261-7366 141 sm] Mansfield Facility — Emergency Action/I Iazardous Waste Contingency Plan Rev. 16 September 2017 Page 3 4.0 GENERAL FACILITY DESCRIPTION AND CHARACTERISTICS OF WASTES The Mansfield facility manufactures precision surgical equipment and instruments. Machining, molding, assembly, polishing, cleaning, packaging, and slipping & receiving operations are conducted at the Mansfield facility. The facility is located in an industrial park and employs approximately 600 people. The facility operates twenty-four hours a day, seven days a week and fifty-two weeks a year. The facility is registered as a LQG of hazardous waste as defined by 310 CMR 30.000. The MADEP generator identification number is MAD985299791. Typical hazardous and non- hazardous industrial wastes generated at the Mansfield facility are shown in Table 1 and Table 2. Table 1 List of Hazardous Wastes Internal Waste Hazard Waste Description Waste Code Number Alcohol used for disinfecting surfaces. 448-E D001 Ignitable Elect ropolish (acidic) rinse water. 448-004 D002, D007 Corrosive and Toxic, (contains phosphoric acid and sulfuric acid) contains > 5 ppm chromium Chloroform (lab waste) used as solvent during 448-X D022 Toxic, contains> 6 small-scale GPC analytical analyses. ppm chloroform Oily rags, pads, etc. used for cleaning surfaces 448-C MA01 Toxic, waste oil around machinery. Cutting, lubricating, and hydraulic oils 448-7 MA01 Toxic, waste oil (petroleum -based) from machining operations. Cell Cleaner Solution - filter cleaner CH292951 D002 Corrosive Alcohols and Silicone for silicone clip process in CH560069 D001 Ignitable CEIII Branson Cleaner/Degreaser Ch289779 MA01 Mansfield Facility —Emergency Action/IIazardous Waste Contingency Plan September 2017 Table 2 List of Non -Hazardous Wastes smith ephew Rev. 16 Pape 4 Waste Description Internal Waste Code Waste Number Hazard Fluorescent low-e bulbs (spent) None MA99 None Water-soluble coolant from machining and grinding operations. 3068433 MA99 None Oalcite detergent and water used for cleaning part surfaces. 448-K MA99 None Vibratory liquid with sludge from part polishing operations. 448-F MA99 None Vibratory sludge with free liquid from part polishing operations. 448-Z MA99 None Antifieeze 448-Y MA99 None HFE-72DE Novec Engineered Fluid CH144753 MA99 None Centerless Grinding Sludge 448-P MA99 None EDM Cleaning — Safety Kleen None MA99 None Kollidon 30 —Non Regulated Solid CH306069 MA99 None Bag/Filters with Water/Titanium 80% Water C11770306 MA99 None Buehler Extec QC Lab Waste CH374399 MA99 None Passivation Waste CH1369686 MA99 None 5.0 HAZARDOUS WASTE STORAGE AREAS Hazardous waste is stored in the hazardous waste/oil storage room. This room's floor, walls, ceiling, and door have a 3-hour fire rating. The room is explosion proof and an automatic sprinkler system and portable fire extinguisher supply fire suppression. In addition to the storage room, 9 satellite hazardous waste acctunulation areas are utilized. A list smithanephew Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 Sentember 2017 Pape 5 of hazardous waste storage/accumulation areas and their locations are presented in Appendix A. Each hazardous waste storage area is identified with postings including the words "hazardous waste" and the hazards associated with the waste being stored. In addition, emergency information is posted at these storage locations and telephones in the area, included, but not limited to: the name(s) and phone number(s) of the emergency coordinator(s); the location(s) of the fire extinguisher(s) and spill control materials; the fire department phone number; and evacuation routes. The Mansfield facility is designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non -sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water which could threaten public health, safety, welfare, or the environment. Steps taken to minimize the potential of fire, explosion, spills, waste release and exposure or personnel to hazardous waste include: • all flammable liquid cabinets are grounded • all drums containing flammable waste are bonded • non -sparking equipment is used on drums containing flammables • containers containing flamrmables are stored in NFPA approved cabinets • flammable waste is kept away from open flame and ignition sources • storage area for flammable waste is bermed • all waste is stored indoors in areas without drains All hazardous waste accumulation areas are inspected weekly. An example weekly inspection log, including hazardous waste storage/accumulation area inspections, is provided in Appendix B. 6.0 RESPONSIBILITY EMERGENCY COORDINATORS AND CHAIN OF COMMAND At all times of operation, there will be at least one Emergency Coordinator either on the facility premises or on call and able to reach the facility and respond to the emergency in less than one hour. The Emergency Coordinator is responsible for managing and coordinating all emergency response measures, including emergencies involving hazardous wastes. Emergency Coordinators are thoroughly familiar with all operations and activities at the Mansfield facility, the location and characteristics of wastes generated the location of all pertinent records, and all aspects of this plan. Further, they have access to all areas of the facility and have the authority necessary to commit all �q smitWephe d Mansfield Facility— Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 6 resources needed to implement this plan. The Primary and Alternate Emergency Coordinators at the Mansfield facility are listed in Appendix C along with phone numbers for emergency services. Emergency Coordinator responsibilities are outlined below: 1. Implement the Emergency Action Plan for all emergencies including those involving chemical and hazardous waste spills, and fires. 2. Ensures that posted evacuation procedures (i.e., maps) are current throughout the facility. 3. Ensures that general contractors understand the provisions of this plan, which include reviewing the plan with each site supervisor. It is the site supervisor's responsibility to review plan requirements with all of their affected employees. 4. Reports to the scene of an incident or fire. 5. Initiates response procedures by contacting on -site and off -site personnel and agencies as appropriate using telephones or cell phones. 6. Coordinates and directs the fimctions of the Emergency Control Center which is located at the Main Lobby or the Visitors' Parking Area. 7. Goes to Central Alarm Panel to assist Fire Department in locating incident or fire scene. 8. During the potential for a large fire, check outside fire main post -indicator valves (PIVs) to ensure they are in the open position and have not been tampered with. 9. Ensures that the required response equipment is available and that personnel are trained in response activities relevant to then responsibilities. �% �s�lth n e�rd Mansfield Facility— Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Paae 7 Department Directors/Managers responsibilities include the following: 1. Ensure that an up-to-date evacuation plan is available in the work area. 2. Train department personnel in the following: - Review evacuation plan, including outside assembly locations. Review emergency exit routes, primary and secondary. - Review emergency shutdown procedures. - Document training. Provide copy of training records to Human Resources. 3. Training is conducted for all employees, including temporary employees. New employees shall be provided training on the first day of employment. The Director/Manager shall inform visitors/contractors who are working in a particular department, without direct supervision from Smith and Nephew Inc. personnel, of the evacuation procedures. 4. Establish procedures for the evacuation of all personnel with special needs. 5. Ensure all personnel evacuate in a prompt and orderly manner when the facility alarm is sounded. Make a sweep of assigned areas (as it is safe to, do so), perform headcount at designated outside assembly location, and report findings to the Emergency Coordinator. 6. Ensure that alarms are clearly audible in all areas under supervision. Report inaudible alarms to the Emergency Coordinator. Employee responsibilities include the following: 1. Follow department evacuation procedures. 2. Leave the building quickly, but in an orderly manner using the designated route(s). If the primary evacuation route is unsafe due to the emergency, use the secondary route or follow the Director's/Manager's instructions. 3. NEVER use elevators during evacuation. If in use when the facility alarm sounds, building elevators are designed to shutdown and lower occupants safely to the first floor where the doors will open. Occupants should then immediately evacuate the elevator and the building. smith&nephew Mansfield Facility —Emergency Action/Hazardous Waste Contnigency Plan Rev. 16 September 2017 Page 8 4. Go to the assigned assembly location outside the building. Advise the Director/Manager of any co-worker that is missing. 5. Only after it is apparent all personnel have exited safely, close corridor doors where convenient upon exit out of the area. 6. Report uncooperative personnel (i.e., those who refuse to evacuate) to the Director/Manager. Do not argue with uncooperative employees and do not delay egress because of these employees. 7. The safe evacuation of visitors is the responsibility of the employee who is hosting the visitor. The visitor is to go to the same outside assembly location with the employee. When contacting the Emergency Coordinator or other response personnel (as necessary), the reporting employee will provide the following information, if available: 1. Company name, location, and phone number; 2. Reporter's name and job title; 3. Time and type of incident (e.g., fire, explosion, release, etc.); 4. Name and quantity of material(s) involved, to the extent lanown; 5. Precise location of incident, to the extent known; 6. The extent of injuries, if any; and, 7. Emergency response actions already undertaken (e.g., building evacuated). 7.0 EMERGENCY PREVENTION AND RESPONSE PROCEDURES This section provides a description of preventative measures in place at Smith & Nephew, as well as general response procedures to be followed in the event of an emergency at the Mansfield facility. The Emergency Coordinators are responsible for implementation of the emergency procedures. hr the event that an Emergency Coordinator is not on -site, the Department Directors/Managers will direct the emergency procedures until an Emergency Coordinator arrives. Mansfield Facility —Emergency Action/Hazardons Waste Contingency Plan Rev. 16 September 2017 Page 9 For purposes of outlining emergency response procedures for spills, all spills are categorized into one of two types: incidental spills which do not pose a hazard to public health, safety, welfare, or the environment, and all other spills. 7.1 EMERGENCY PREVENTION • The Smith & Nephew facility has been designed and constructed, and is operated, to prevent and minimize the possibility of a flu -eat to public health, safety, or welfare, or the environment from a fire, explosion, or any other unplanned sudden or non -sudden release of hazardous waste or hazardous waste constituents to air, soil, surface water, or ground water. The following outlines potential hazards and preventive measures in place at Smith & Nephew: o Uncontrolled Reaction of Incompatible Wastes: Incompatible wastes are separated from each other by storing them in separate rooms or in separate containment areas, and are not stored within the same area unless separate containment is provided. o Hazards During Unloading: Smith & Nephew personnel oversee hazardous waste loading activities to ensure that containers are securely closed prior to unloading, and that they are handled in a safe manner during unloading to prevent possible spills. Hazardous waste containers are secured on hand -trucks, fork trucks, or other appropriate transfer equipment prior to transfer. o Runoff from Hazardous Waste Storage Areas: The hazardous waste storage areas at Smith & Nephew, and all satellite accumulation areas, are located inside facility buildings; therefore, there is no potential for runoff. The hazardous waste storage room is provided with secondary containment, and there are no floor drains in the area. o Prevent Flooding: The Mansfield facility is not located within the 100-year flood zone; therefore, flooding is higlrly unlikely. o Mitigate Effects of Equipment Failure/Power Outages: The Mansfield facility is equipped with emergency generators to provide' emergency power in the event of power outages. Facility equipment is maintained in accordance with manufacturer's specifications to minimize the possibility of failure. o Prevent Hazards from Fires, Explosions, and Spills: Smith & Nephew maintains Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 10 fire and spill control equipment as detailed in Section 9 of this plan. In addition, emergency procedures are in place as described below. o Prevent Exposure of Personnel to Hazardous Wastes: Only appropriately trained personnel are authorized to handle hazardous wastes at the facility. In addition, personal protective equipment (as described in Section 9.4) and first aid equipment (as described in Section 9.5) is maintained at the facility. 7.2 Incidental Spills Incidental spills are spills of hazardous materials that can be absorbed, neutralized or otherwise controlled at the time of the release by employees in the immediate area and do not pose a hazard to public health, safety, welfare, or the environment, or spills of materials that do not represent imminent danger to the responder's life or health. An incidental spill does not pose a hazard to the employee, which would cause any greater exposure to the chemical than that resulting from normal acceptable occupational use. In the event of an incidental spill, the procedures outlined below shall be followed: 1. Identify the type of material spilled (use labels, appearance, odor, etc.). 2. Contact Department Director/Manager. 3. Clean up the spill using appropriate absorbent material. 4. Dispose of spill cleanup materials in accordance with applicable state and federal regulations in consultation with Health, Safety and Environment (HSE) or Facilities. 5. If there are any questions concerning the disposition of cleanup materials, or the labeling of the containers, contact Health, Safety & Environment or Facilities. 6. The Massachusetts Contingency Plan (310 CMR 40.0000) requires reporting to the MassDEP as soon as possible but not more than two hours after obtaining knowledge that a release exceeds the Reportable Quantity (RQ) specified at 310 CMR 40.0352 or 40.1600 (see 310 CMR 40.0311). The RQ for petroleum oil is 10 gallons. smithftephew Mansfield Facility —Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 11 7. Report spill that exceed Reportable Quantity as defined in the State and Federal regulations to the Mansfield Fire Department. 8. The National Response Center must be notified for oil releases that cause a visible sheen on surface water (see 40 C.F.R. 110). 7.3 All Other Spills of Wastes In the event of a hazardous material spill that is too large to be handled by a single employee, the procedures outlined below shall be followed: 1. As it is safe to do so, determine the source of the leak or spill and identify type and amount of material spilled to the extent possible. Classify the characteristics of the waste spilled and determine areas affected. 2. Contact an Emergency Coordinator, Manager and/or Manager, Health, Safety & Environment. Give the exact location, status, and nature of the incident. 3. The Emergency Coordinator will ensure internal facility alarms or communication systems are activated, as appropriate. 4. The Emergency Coordinator shall contact properly licensed and trained emergency response professionals, as appropriate. 5. The Emergency Coordinator will secure the spill area so that only emergency response personnel have access. 6. The Emergency Coordinator, or designated persons, will account for all personnel and ensure they are isolated from danger. 7. The Emergency Coordinator will arrange for emergency services for any injured personnel. 8. The Emergency Coordinator, working with appropriate emergency responders, will fitrther identify the character, exact source, amount, and extent of released material. Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan September 2017 smithMephew Rev. 16 Pace 12 9. The Emergency Coordinator, working with appropriate emergency responders, will disperse absorbent materials and/or booms to prevent the spill from spreading. 10. The Emergency Coordinator, working with appropriate emergency responders, will restrict all sources of ignition and ready fire suppression equipment. 11. The Emergency Coordinator and emergency responders will assess potential hazards to public health, safety, welfare, or the environment that may result fiom the emergency. This assessment must consider both direct and indirect effects of the release, fire or explosion (e.g., the effects of any toxic, irritating, or asphyxiating gases that are generated, or the effects of any hazardous surface water run-off from water or chemical agents used to control fire and heat -induced explosions). Additional licensed outside emergency contractors may be contacted, as appropriate. 12. The Emergency Coordinator will determine if any other areas of the facility are affected by the spill and secure those areas if necessary. 13. The Emergency Coordinator will monitor operations for any potential problems. 14. The Emergency Coordinator will notify appropriate federal, state, or other local emergency response teams if necessary. 15. The Emergency Coordinator, working with emergency responders, will decide if the facility needs to be evacuated. If told to evacuate, employees must do so immediately. 7.4 Small Fires For small fires that present minimal risk to employee health, safety, welfare, or the environment, the procedures outlined below shall be followed: 1. Call911. 2. If trained in portable extinguisher use, extinguish the fire using a proper fire extinguisher a smith&ne he Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 Sentember 2017 Page 13 directed at the base of the fire taking precautions to avoid spreading of any burring liquid. 3. Contact the Emergency Coordinator. 4. Complete incident report of fire. Although periodic portable extinguisher training is provided, Smith and Nephew Inc. does not advocate fire fighting by its employees. Employees should not attempt to fight any fire when there is an immediate danger from explosion or fumes. Any fire involving a flammable liquid, such as alcohol, may result in an explosion. Toxic vapors are given off when most chemicals and man- made articles burn, especially plastic. Any smoke or vapor is potentially toxic and is always hazardous. 7.5 Large Fires and Explosions For fires that cannot be extinguished safely using portable extinguishers and explosions, the procedures outlined below shall be followed: 1. Activate the internal facility alarm system to notify all facility personnel. The internal system is connected directly to an external service that notifies the Fire Department. 2. If the internal alarm system cannot be safety activated, call the Fire Department (dial 911). 3. Contact an Emergency Coordinator. The Emergency Coordinator shall ensure internal , facility alarms or communication systems are activated. 4. The Emergency Coordinator (or designee) will check outside fire main post -indicator valves (PIVs) to ensure they are in the open position and have not been tampered with. 5. Evacuate the building. 6. Upon arrival of the Fire Department (west side building entrance, fire panel location), ensure access inside the building is provided. At this time, primary response authority is designated to fire response personnel. smithUephew Mansfield Facility —Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Pape 14 7. The Fire Department and/or Emergency Coordinator will arrange for emergency set -vices for any injured personnel. 8. The Emergency Coordinator will attempt to identify the character, exact source, amount, and extent of any released material, as appropriate. 9. The Emergency Coordinator (with the Fire Department) will assess possible hazards to public health, safety, welfare, or the enviromnent that may result from the emergency. This assessment should consider both direct and indirect effects of the incident (e.g., the effects of any toxic, irritating, or asphyxiating gases that are generated or the effects of any hazardous surface water run-off from water or chemical agents used to control fire and heat -induced explosions). 10. Waste cleanup after a large fire will be conducted using licensed outside contractors, as appropriate. 7.6 Medical Emergencies For injuries requiring first aid, contact a Medical Emergency Response Team (MERT) member. These personnel are certified in automated external defibrillator (AED) operation, basic first aid, and CPR procedures. Three Medtronic LifePak CR Plus AEDs are located at the Mansfield facility, (1) the fast floor outside the Bic, Skills lab, (2) the first floor outside Human Resources, and (3) second floor near restrooms. The unit is located in a semi -recessed wall mounted case, which is equipped with a local alarm and is connected to the building security system. In the event - the AED is removed, the building security system is notified and emergency professionals are contacted. A current list of MERT members is posted in each department. For all other medical situations, the procedures to follow include: 1. If victim can be safely moved, move to fresh air as appropriate. Pay special attention to back or neck injuries. In these cases, moving a victim should only be done when imminent danger is present. 2. Contact emergency professionals (dial 911), 3. If the employee has come in contact with hazardous materials/chemicals, the skin and/or smitlAnephew Mansfield Facility —Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 15 eyes should be flushed with running water for at least 15 minutes, as appropriate. 4. Remove and isolate contaminated clothing and shoes, as appropriate. Contact qualified and trained personnel to administer the AED, first aid, and CPR. In the event a MERT member is not available and the emergency requires the use of the AED then the AED can be used by anyone feeling conformable to do so. 7.7 Following Emergencies Subsequent to any of the aforementioned emergencies, an Emergency Coordinator will perform the following tasks: 1. Ensure that all materials resulting from the release, fire, or explosion are properly treated, stored, or disposed. 2. Ensure that no waste that may be incompatible with the released material is treated, stored, or disposed of until cleanup procedures are completed. 3. Ensure that all emergency equipment is cleaned and fit for its intended use before operations are resumed. 4. If the facility stops operation in response to a fire, explosion, or release, assess the building for leaks, pressure build-up, gas generation, or ruptures in valves, pipes, or other equipment, as appropriate. 5. Record in Appendix D the required information to document the incident. 6. Notify proper authorities that cleanup is complete and that emergency equipment has been cleaned and/or replaced, as appropriate. 8.0 EVACUATION PLAN When the facility internal alarm is triggered, the building shall be evacuated. If the Emergency Coordinator determines that an isolated incident presents a potential hazard to employee health, safety, or welfare, the facility, or at a minimum, the affected area will be evacuated. If the incident poses a potential threat to the surrounding community, the Emergency Coordinator will contact the smith&nephew Mansfield Facility — Emergency Acfion/IIazardous Waste Contingency Plan Rev, 16 September 2017 Page 16 proper authorities. Emergency professionals will determine appropriate evacuation plans/procedures for surrounding areas. The objective of the evacuation plan is to minimize potential health hazards from an incidental spill, fire, or explosion. Evacuation route maps are posted throughout the facility and Appendix E highlights the building exits and outside assembly areas. • Decision to Evacuate: When the facility internal alarm is triggered, the building shall be evacuated. If the alarm does not sound, the decision to evacuate will be made by the Emergency Coordinator or the Fire Department. The decision will be based on the Emergency Coordinator's experience with the facility and the following evaluation of the incident: 1. Nature and toxicity of materials involved. 2. Possibility of (or actual) explosion or spreading fire. 3. Possibility of (or actual) hazardous or toxic release into the air. 4. Prevailing wind direction. • Evacuation Procedures: Once evacuation is initiated, the Emergency Coordinator will direct the evacuation following the procedures outlined below: 1. Employees shall secure their areas, as it is safe to do so. 2. Evacuation is to proceed along designated evacuation routes miless otherwise directed by the Emergency Coordinator or emergency professionals. All personnel shall evacuate calmly and in an orderly manner. Employees are to directly exit the facility without hesitation or stopping. Employees shall meet at the outside assembly area designated for that department so that the Director/Manager/Evacuation Leader can account for them. 3. All employees shall ensure that any unauthorized person is prevented from re-entering the building. 4. Directors/Managers/Evacuation Leaders shall account for all personnel to ensure that everyone has been evacuated. The visitor's logs at the fi•ont desk in the lobby and back door shipping entrance will be checked to ensure all visitors have been evacuated. Visitors should remain with their facility contact, as appropriate. If someone cannot be accounted for, the Emergency Coordinator, working with emergency response personnel, will smithilne how Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 17 determine how to proceed in locating any missing person(s). 5. The Emergency Coordinator will decide when and if the facility can be re-entered. Personnel shall not re-enter the building without permission from the Emergency Coordinator and/or Fire Department. 6. The Emergency Coordinator (with emergency professionals) will coordinate calls to the local health center and hospitals to treat any injured people, as appropriate. 9.0 EMERGENCY RESPONSE EQUIPMENT, SIGNS, AND MARKINGS The following is a summary of emergency equipment available at the facility: 1. An internal communications or alarm system capable of providing emergency instruction (voice or signal) to facility personnel; 2. A device, such as a telephone (immediately available at the scene of operations) or a hand- held two-way radio/telephone, capable of summoning emergency assistance from local police departments, fire department, or State or local emergency response teams; 3. Portable fire extinguishers, fire control equipment (including special extinguishing equipment, such as that using foam, inert gas, or dry chemicals), spill control equipment, and decontamination equipment; 4. Water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems; 5. Clear markings identifying all exits so that everyone in the facility can quickly find their way out of the facility during the emergency; and, 6. An up-to-date written list containing the following information, a copy of which list will be posted near the telephone at the site of hazardous waste accumulation. The name(s) and telephone number(s) of the Emergency Coordinator(s); the location(s) of the fire extinguisher(s) and spill control material(s), and, if present, the fire alarm; the telephone number of the fire department, or, if there is a direct alarm system, instructions on how to use it, or both; and, evacuation routes, where applicable. �q smithftepheA4 Mansfield Facility — Emergency Action/liazardous Waste Contingency Plan Rev. 16 September 2017 Patze 18 The following additional information is provided regarding emergency equipment: 9.1 Communication Systems An internal alarm system capable of providing immediate emergency instruction (signal) to facility personnel is operational. Iii addition, telephones are located throughout the facility to contact MERT members and emergency professionals. Building alarm pull boxes, which notify the Fire Department, are located at numerous locations throughout the building. A list of emergency information, instructions, and phone numbers is posted next to each phone near a hazardous waste storage area. 9.2 Fire Control Equipment The facility has an automatic sprinkler system for fire suppression. In addition, portable fire extinguishers are located throughout the building. A detailed listing of the location and capabilities of portable fire extinguishers is presented in Appendix F. Portable fire extinguishers located throughout the building are predominantly dry chemical. Dry chemical extinguishers can be used to extinguish Class A, Class B, and Class C fires. Class A fires involve wood, paper, rags, etc. Class B fires involve flannnable or combustible liquids. Class C fires involve electrical equipment. Class D extinguishers are used on flamrnable metals. At least three Class D extinguishers are also present at the facility and are staged in the Titanium cell (TIC), Titanium Hand FinisMng and the Chip Spinning Room, nearby titanium scrap storage. The facility also has an automatic Halon fire suppression system in the computer room (IS Server Room) and an Ansul dry chemical system installed over the cafeteria grills. Numerous carbon dioxide (CO2) fire suppression systems have been installed on manufacturing equipment that has the potential to generate fires (e.g., uses combustible machining fluids). A detailed listing depicting the location of all CO2 file suppression equipment is provided in Appendix G. All fire control equipment present at the facility is properly maintained and inspected (as required) by outside contractors that specialize in these systems. smith nephew Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 Sentember2017 Page 19 9.3 Spill Control Equipment Spill control equipment is located in the hazardous waste/oil storage room. Equipment inside the hazardous waste/waste oil storage room includes absorbent materials, shovels, brooms, and an over pack drum. Additional satellite spill control stations are also located throughout manufacturing areas to control incidental spills. A complete list of spill control equipment is provided in Appendix H. 9.4 Personal Protective Equipment (PPE) Chemical goggles, face shields, aprons, gloves, safety glasses, and other PPE are kept in department cabinets, as appropriate. A licensed outside contractor would handle any incident involving hazardous materials/waste (other than incidental) requiring the use of personal protective equipment. A complete list of spill control equipment including available PPE for emergencies is provided in Appendix H. 9.5 First Aid Equipment There are 4 fully stocked satellite first aid stations maintained at the facility. Specific personnel on all shifts (i.e., MERT members) have been trained in AED operations, CPR, and First Aid. Three Medtronic LifePak CR Plus AEDs are located at the Mansfield facility, (1) the first floor outside the Bio Skills lab, (2) the first floor outside Human Resources, and (3) second floor near the restrooms. The units are located in a semi -recessed wall -mounted case, which is equipped with a local alarm and is connected to the building security system. In the event the AED is removed, the building security system is notified and emergency professionals are contacted. Qualified and trained personnel shall administer the AED, first aid, and CPR. All though in a real emergency, the AED would be used by anyone comfortable to do so. For any medical treatment beyond basic first aid, contact emergency professionals by dialing 911 on any phone located at the facility. 9.6 Testing and Maintenance of Equipment The Emergency Coordinators are responsible for ensuring that all conunun ications or alarm smithMephew Mansfield Facility — Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Pape 20 systems, fire protection equipment, and spill control equipment are tested and maintained as necessary to assure its proper operation in time of emergency. The facility's fire sprinkler systems, fire alarm and suppression detection systems, special hazard/gas suppression systems, kitchen fire suppression system, and portable fire extinguishers are maintained and inspected, as appropriate, by a licensed fire suppression company. Periodic fire extinguisher training is also offered to employees. Emergency lighting is inspected annually. All test/inspection records are maintained by Facilities. 9.7 Required Aisle Space Adequate aisle space (>3 feet) is maintained to allow the unobstructed movement of personnel, fire protection equipment, and spill control equipment to any area of facility operations in an emergency. Aisle space is inspected at least weekly in all hazardous waste accumulation areas. 10.0 ARRANGEMENTS WITH LOCAL AUTHORITIES Facilities personnel maintain open communication with local authorities such as: 1. Arrangements to familiarize Mansfield police and fire departments with: • Facility layout; • Properties of hazardous waste handled at the facility and associated hazards; • Places where facility personnel would normally be working; • Entrances to the facility; • Evacuation routes 1. Agreements with emergency response teams/contractors, as appropriate 2. Arrangements to familiarize the Mansfield Board of Health and Sturdy Memorial Hospital with the properties of hazardous waste handled at the facility and the types of injuries or illnesses which could result from fires, explosions, or releases at the facility. The Mansfield Fire Department conducts toms as needed to familiarize their persomnel with the smutWephew Mansfield Facility —Emergency Action/Hazardous Waste Contingency Plan Rev. 16 September 2017 Page 21 facility's layout, inspect fire suppression systems, means of egress, etc. The fire department has been provided a diagram of the facility showing exits and location of CO2 fire suppression systems. The Mansfield facility also makes arrangements with the Mansfield Police Department and emergency response contractors (i.e., Clean Harbors, Inc.), as appropriate. 11.0 NOTIFICATION REQUIREMENTS Whenever there is a chance for, or an actual emergency, appropriate authorities shall be contacted and contractors with designated roles if their help is needed. hi the event of an emergency that could threaten public health, safety, or welfare of the environment, the following contacts should be made by the Emergency Coordinator (or designee) as appropriate: Massachusetts Department of Environmental Protection (Spill Hotline): (888) 304-1133 Massachusetts State Police: (617) 566-4500 National Response Center: (800) 424-8802 Appendix C provides additional emergency contact telephone numbers, as appropriate. 12.0 PLAN AMENDMENTS This Emergency Action Plan will be reviewed and amended, if necessary, whenever: 1. The plan fails in an emergency. 2. The facility changes its design, construction, operation, maintenance, or other circumstances in a way that materially increases the potential for fires, explosions, or releases of hazardous waste or hazardous waste constituents, or changes the response necessary in an emergency. 3. The list of Emergency Coordinators changes. 4. The list of emergency equipment changes. 5. Any applicable State or Federal regulations are revised. If the plan is amended, updated copies will be distributed to personnel, agencies, and organizations, as appropriate. APPENDIX A List anti Location of Hazardous Waste Storage/Accumulation Areas ,-% smith eph w Mansfield Facility — Appendix A May 2017 Hazardous Waste Storage Room HW Storage Area Approximate Location Quantity (gallons) HW Storage Room. 250 Southwest coiner of the building, to the right of the Shipping dock. Satellite Hazardous Waste Accumulation Areas HW Satellite Accumulation Approximate Quantity (gallons) Location 1. Electropolish rinse water and electro olish rags with rinse water. 55 Behind Electropolish machine. 2. Chloroform/ Synthesis Processing Waste 10 Polymer Lab, beneath ftune hood, inside locked cabinet. 37 Oil rags/pads and waste oil. 55 Inside Chip Spinning Room. 4. Isopropyl Alcohol 10 R&D Model Shop 5. Isopropyl Alcohol 10 TOC Cell 6. Isopropyl Alcohol 10 BURR Cell 7. Vacuum Pump Oil 10 Outside Alley — waste for Chillers in CEI 8. .S'ilicone/1PA Waste 55 Outside CEIII 9. Branson Cleaner/Degreaser 55 Outside CEIII Weel(Iy Audit Log WEEKLY AUDIT LOG FOR THE MONTH OF , 20_ (REPORT ANY NEGATIVE FINDINGS TO FACILITIES and ENVIRONMENTAL, HEALTH, SAFETY) WRITE DATE AUDIT PERFORMED-. WEEK I WEEK2WEEK 3 WEEK4WEEK COMMENTS/REPAIRS/ACTIONS NEEDED OR COMPLETED FM Inspections „smiih&nephew FACTORY MUTUAL WEEKLY FIRE PREVENTION AUDIT: 1. Are fire extinguishers accessible with signs posted and properly charged? Are any extinguishers missing? 2. Is outside PIVs (2) open and locked? 2a. Monthly - Spring test to ensure valves are in the open position and functional. 3. Are all sprinkler room control valves (4) open and locked? 4. Are emergency exit fire doors properly closed and unobstructed? 5. Are sufficient automatic sprinkler heads available with minimum 18-inch clearance from stored objects? 6. Fire sprinkler system and alarm test status current? 7. Satisfactory housekeeping (e.g., safety cans, outside designated smoking areas, storage)? CONTROL OF HAZARDOUS ENERGY (LO/TO) 1. Are current LO/TO devices in place as appropriate? 2. Does control meet requirements per OSHA 29 CFR 1910.147/EOP 1400159? Waste & Chemical Storage Inspections SPILL CONTROL CABINET: 1. Sufficient and appropriate contents? 2. Satisfactory housekee In ? AIR COMPRESSOR ROOMS: 1. Satisfactory housekeeping? 2. Sufficient clearance for panels i.e. 3 feel)? MAIN ELECTRIC ROOM & PANELS: 1. Satisfactory housekeeping? 2. Sufficient clearance for panels i.e., 3 feet)? OUTSIDE GAS STORAGE: 1. Satisfactory housekeeping? 2. No evidence of any danger concerns? Hazardous Waste STORAGE ROOM: 1. Proper labeling including "Hazardous Waste", name of the waste (e.g., Isopropyl Alcohol (D001)), and the waste hazard (e.g., corrosive (D002))? 2. Each label visible? 3. Have all containers in storage been on -site for less then 90 days (refer to the accumulation start date on each container)? 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers in good condition (i.e., free from leaks, bulges, corrosion)? 6. Is adequate aisle space maintained? 7. Is the floor free from cracks/gaps? 8. Is the room posted "Hazardous Waste Storage? 9. Satisfactory housekeeping? 10. Flammable containers grounded? Hazardous Waste Satellite Accumulation - ELECTROPOLISH: 1. Proper labeling including "Hazardous .. Waste", name of the waste (e.g., Electropolish ' Rinse), and the waste hazard (e.g., corrosive (D002))? 2. Each label visible? Page 1 of 2 312017 WEEKLY AUDIT LOG FOR THE MONTH OF , 20 (REPORT ANY NEGATIVE FINDINGS TO FACILITIES and ENVIRONMENTAL, HEALTH, SAFETY) WRITE DATE AUDIT PERFORMED-, WEEK 1 WEEK2WEEK 3 WEEK 4 WEEK il COMMENTSIREPAIRS/ACTIONS NEEDED OR COMPLETED 3. Each container not full? Or if full, for less is then 3 days? ' 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers in good condition (i.e., free from leaks, bulges, corrosion)? 6. One container per waste type? 7. <55 gallons of HW in area? 8. HW stored within demarcated area? 9. Housekeeping satisfactory? HW Satellite Accumulation - IPA TOC CELL: Same as above HW Satellite Accumulation - IPA BURR Cell: Same as above HW Satellite Accumulation - IPA R&D Model Shop: Same as above HW Satellite Accumulation - Chlorform POLYMER LAB: Same as above HW Satellite Accumulation - Silicone Waste CEIII: Same as above HW Satellite Accumulation - Chiller Pump Waste Outside SERVICE ALLEY: Same as above ALCOHOL RECYCLER: Regulated Recyclable Material 1. Proper labeling including "Hazardous Waste", name of the waste (e.g„ Isopropyl Alcohol (D001)), and the waste hazard (e.g., corrosive (D002))? 2. Each label visible? 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers in good condition (i.e., free from leaks, bulges, corrosion)? 6. Is adequate aisle space maintained? 7. Is the floor free from cracks/gaps? 9. Satisfactory housekeeping? 10. Flammable containers grounded? ALCOHOL ROOM: Flammable Liquid 1. Alcohol bin closes properly? 2. Air guns are In good working condition? 3. Air lines are in good working condition i.e. leaks? 4. Flammable containers grounded? 5. Satisfactory housekeeping? First Aid Cabinet & AED Inspections: 1. Sufficient and appropriate FA supplies? 2. Sufficient rubber gloves in dispenser? 3. Satisfactory housekeeping? 4. Medical waste storage appropriate? 5. "OK" symbol visible on AED readiness display? 6. Has Use By date on electrode package? 7. Other AED emergency supplies adequate! AUDITORS NAME -+ Page 2 of 2 3/2017 WEEKLY AUDIT LOG FOR THE MONTH OF , 20_ (REPORT ANY NEGATIVE FINDINGS TO FACILITIES and ENVIRONMENTAL, HEALTH, SAFETY) WRITE DATE AUDIT PERFORMED—, WEEK1WEEK2 WEEK3 WEEK4 WEEK COMMENTS/REPAIRS/ACTIONS NEEDED OR COMPLETED JFM inspections %e smith&nephew FACTORY MUTUAL WEEKLY FIRE PREVENTION AUDIT: 1. Are fire extinguishers accessible with signs posted and properly charged? Are any extinguishers missing? 2. Is outside PIVs (2) open and locked? 2a. Monthly - Spring test to ensure valves are in the open position and functional. 3. Are all sprinkler room control valves (4) open and locked? 4. Are emergency exit fire doors properly closed and unobstructed? 5. Are sufficient automatic sprinkler heads available with minimum 18-inch clearance from stored objects? 6. Fire sprinkler system and alarm test status current? 7. Satisfactory housekeeping (e.g., safety cans, outside designated smoking areas, storage)? CONTROL OF HAZARDOUS ENERGY (LO/TO) 1. Are current LO/TO devices in place as appropriate? 2. Does control meet requirements per OSHA 29 CFR 1910.147/EOP 1400159? Waste & Chemical Storage Inspections SPILL CONTROL CABINET: 1. Sufficient and appropriate contents? 2. Satisfactory housekeeping? AIR COMPRESSOR ROOMS: 1, Satisfactory housekeeping? 2. Sufficient clearance for panels i.e., 3 feet)? Fi housekeeping? Waste", name of the waste (e.g., Isopropyl Alcohol (DO01)), and the waste hazard (e.g,, corrosive (DO02))? 2. Each label visible? 3. Have all containers in storage been on -site for less then 90 days (refer to the accumulation start date on each container)? 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers in good condition (i.e., free from leaks, bulges, corrosion)? 6, Is adequate aisle space maintained? 7. Is the floor free from cracks/gaps? 8. Is the room posted "Hazardous Waste Storage? 9. Satisfactory housekeeping? Waste", name of the waste (e.g„ Eleclropolish Rinse), and the waste hazard (e.g., corrosive (DOD2))? 2. Each label visible? Page 1 of 2 3/2017 WEEKLY AUDIT LOG FOR THE MONTH OF , 20_ (REPORT ANY NEGATIVE FINDINGS TO FACILITIES and ENVIRONMENTAL, HEALTH, SAFETY) WRITE DATE AUDIT PERFORMED— WEEK WEEK 2 WEEK3WEEK 4 WEEK COMMENTS/REPAIRS/ACTIONS NEEDED OR COMPLETED 3. Each container not full? Or if full, for less then 3 days? 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers In good condition (i.e., free from leaks, bulges, corrosion)? 6. One container per waste type? 7. <55 gallons of HW in area? 8. HW stored within demarcated area? 9. Housekeeping satisfacto ? HW Satellite Accumulation - IPA TOC CELL: Same as above HW Satellite Accumulation- IPA BURR Cell: Same as above HW Satellite Accumulation - IPA R&D Model Shop: Same as above HW Satellite Accumulation - Chlorform POLYMER LAB: Same as above HW Satellite Accumulation - Silicone Waste CEIII: Same as above HW Satellite Accumulation - Chiller Pump Waste Outside SERVICE ALLEY: Same as above ALCOHOL RECYCLER: Regulated Recyclable Material 1. Proper labeling including "Hazardous Waste", name of the waste (e.g., Isopropyl Alcohol (D001)), and the waste hazard (e.g., corrosive (D002))? 2. Each label visible? 4. Containers properly closed (e.g., bungs in - place, funnels removed)? 5. Containers In good condition (i.e., free from leaks, bulges, corrosion)? 6. Is adequate aisle space maintained? 7. Is the floor free from cracks/gaps? 9. Satisfactory housekeeping? 10. Flammable containers rounded? ALCOHOL ROOM: Flammable Liquid 1. Alcohol bin closes properly? 2. Air guns are in good working condition? 3. Air lines are in good working condition i.e. leaks? 4. Flammable containers grounded? 5. Satisfactory housekeeping? First Aid Cabinet & AED Inspections: 1. Sufficient and appropriate FA supplies? 2. Sufficient rubber gloves in dispenser? 3. Satisfactory housekeeping? 4. Medical waste storage appropriate? 5. "OK" symbol visible on AED readiness display? 6. Has Use By date on electrode package? 7. Other AED emergency supplies adequate? AUDITORS NAME --� Page 2 or 2 3/2017 wniftnephew APPENDIX C List of Emergency Coordinators and Emergency Services Plimre Numbers Mansfield Facility — Appendix C 130 Forbes September 2017 �% smith ephew In Case of an Emergency Individual/AgencyIndividual/Agency Phone Number Primary Emergency Coordinator— Ed Martynowslci Work Phone (508) 261-3693 Cell Phone (781) 589-4653 Primary Emergency Coordinator — Denice Parente Work Phone (508) 261-3697 Cell Phone (508) 844-8944 Primary Emergency Coordinator— Russ Manley Work Phone (508) 261-3666 Cell Phone (781) 589-4651 Manufacturing, Senior Director- Nathan Trembath Work Phone (508) 337 4078 Cell Phone (508) 446-6209 Mansfield Emergency Services 911 Fire Department (508) 261-7321 Police Department (508) 261-7300 Emergency Response (Oil/Chemical Spills) — Clean Harbors (800) 645-8265 Gas Leak — Columbia Gas (800) 525-8222 Power Outage — Mansfield Municipal Electric Department Work Hours (508) 261-7361 After Hours (508) 261-7300 Mansfield Water Department (508) 261-7330 ext.484 Poison Control Center (800) 682-9211 Sturdy Memorial Hospital (508) 222-5200 General Information EPA Generator ID Number: MAD985299791 Spill control equipment is located in the HW/Oil Storage room, the compressor room, and at satellite locations. Fire extinguishers are located throughout the building and are marked with signs indicating presence. Fixed extinguishing systems (e.g., CO2, Halon) are area/equipment specific. If you work in these areas, ensure you have a proper understanding regarding the operation of these systems. Fire alarms are located at every exit. REMEMBER !!! REACT -- Never assume a false alarm! Evacuate the building promptly, and in a calm and orderly mamier. MEET — An Emergency Coordinator shall meet emergency professionals (e.g., Fire Department) at the west building entrance (i.e., alarm panel location). This area is the Emergency Command Center, where decisions are made. SWEEP —Directors/Managers shall perform localized sweeps of their areas to ensure prompt evacuation- Facilities/Emergency Coordinators personnel shall perform global sweeps, as it is safe to do so, to ensure complete building evacuation. ASSEMBLE — Proceed directly to your designated outside Assembly Area. Review applicable evacuation maps and confirm with your manager/supervisor the appropriate area to assemble. If you exit the building from an atypical location, proceed immediately to your designated Assembly Area. Page I Mansfield Facility —Appendix C 130 Forbes September 2017 smithF nephew In Case of an Emergency COUNT — Directors/Managers/Evacuation Leaders are responsible for counting personnel within outside Assembly Areas, to ensure complete evacuation. Any missing personnel should be reported to the Command Center/Emergency Coordinators immediately. Sturdy Memorial Hospital (Directions): Exit S&N property, go right. Turn left on Commercial St./RT 140 North. Merge onto I-95 South. Take Exit 5 (RT 152 Attleboro/Plainville). Turn left onto Robert F. Toner Blvd. Make slight right onto N. Main St./RT 152. Turn Left onto Sanford St. Turn right on Bank St. Turn left onto Park St., hospital is at 211 Park St. LOOK FOR BLUE f°H" SIGNS ENROUTE. Other Emergency Contact Numbers Matt Griffith - Blades Manager Work Phone (508) 261-3638 Cell Phone (781) 500-9045 Peter Furfari — Implants Manager Work Phone (508) 261-3665 Cell Phone 508) 243-3150 Jennifer Hall — Instruments Manager Work Phone (508) 261-3677 (781)254-2715 Neal Bowman — Maintenance Manager Work Phone (508) 261-3639 Cell Phone (508) 633-9872 Howie Haggas — Materials Manager Work Phone (508) 261-3646 Cell Phone (508) 962-3238 Joel Briner — Director Downstream Quality Work Phone (508) 261-3687 Cell Phone (508) 361-3544 77 f HRISupervisors/MechainYes s Karla LeMarre HR Work Phone (508) 261-3631 Jim Krajewski — lst Blades Supervisor Work Phone (508) 261-3794 Peter Blackler— lst Blades Supervisor Work Phone (508) 261-3622 Sarah Cenedella — Vt Shift Implants Supervisor Work Phone (508) 337-4029 Dave Do — lst Shift Instruments Supervisor Work Phone (508) 261-3796 Mike Lee — 2" Shift Instruments Supervisor Work Phone (508) 261-3712 Shawn Stoddard — 2" Shift Implants Supervisor Work Phone (508) 261-3622 David Paille — 2" Shift Blades Supervisor Work Phone (508) 261-3645 Page 2 Mansfield Facility —Appendix C 130 Forbes September 2017 „% moth neph w In Case of an Emergency Ted Foeller — 2” Shift Blades Supervisor Work Phone (508) 337-4065 Joe Ross — 3` Shift Blades Supervisor Work Phone (508) 337-4084 John Howland — 3` Shrift Implants & Instruments Supervisor Work Phone (508) 261-3747 Frank Penney — 4" Shift Blades Supervisor Work Phone (508) 261-3732 Mechanics Mezzanine Work Phone (508) 261-3771 Page 3 6 �) smithl8mephew " MUM Emergency Record Log Mansfield Facility — Appendix D July 2017 Emergency Record Log ,� smith ephew Type of Date Time emergency (fire, Location Actions taken (during and after) spill, etc.) 04/04/2007 5:30 Fire Nakamora Nakamora machine's fire suppression system discharged a.m. Machine because the coolant flashpoint was to low at >260°. Coolant has been changed to >330°. Employees evacuated and Mansfield Fire Department arrived assessed the situation and gave the "all clear' allowing employees to enter the facility. 07/25/2007 7:50 Fire E-16 BIGI cell The E-16 overheated setting off the fire suppression due a.m. to operator forgot to turn the oil release switch back on after removing chips. Employees evacuated and Mansfield Fire Department arrived assessed the situation and gave the "all clear' allowing employees to enter the facility. 10/30/2007 6:00 Fire Electro polish The fire suppression discharged at the Electro polish due a.m. to charring and discoloration from the electrodes on the plastic drip tank slanted piece. Employees evacuated and Mansfield Fire Department arrived assessed the situation and gave the "all clear' allowing employees to enter the facility. 12/02/2007 12:30 Smoke Duct Vents The fire alarms were sent off due to excess residue in the a.m. vent ducts. Within the next few days the ducts were cleaned. Employees evacuated, Mansfield Fire Department arrived, assessed the situation and gave the "all clear" allowing employees to enter the facility. 12/16/2007 8:30 Fire E-32 Shaft Cell There was a small fire within the machining envelope. a.m. Operator was using wrong tooling inside machine. Since then the operator has been re-trained. Employees evacuated and Mansfield Fire Department arrived assessed the situation and gave the "all clear' allowing employees to enter the facility. 07/26/2008 7:30 Smoke Duct Vents The fire alarms went off on Saturday morning around a.m. 7:30 a.m. due to a dirty duct smoke detector. Simplex were on site to do fire alarm testing so we had them take care of the problem. The second time was the testing of the fire alarm system by Simplex. 10/14/2008 1:41 Spill Polymer Lab A trained employee working in the Polymer Lab was p.m. placing a bottle of chloroform into the chemical cabinet, the bottle slipped out of his hand smashing on the floor. The employee evacuated the room closing the door behind him. Emergency Coordinators on site were called to the scene. The room is equipped with a fume hood, AC was turned off, area was secured and Clean Harbor's emergency services were called for clean—up. Page 1 Mansfield Facility —Appendix D smith e h w July 2017 Emergency Record Log 01/26/2009 11:35 Smoke BIGI Around 11:35 pm the alarms were set off by the E16-3 p.m. In the BIGI cell. It looks like the tool chipped and the diameter was too big to fit into the sub spindle. Every one left the building safely. The fire dept. showed up looked at the machine shut off the alarm and cleared us to go back in. 05/28/2009 11:45 Fire Nakamora We have verified the machine oil levels and chips were in a.m. Machine normal operating range. The oil type has also been verified to be the Hardcut oil that has a higher flash point than the previous oil that was used. Investigation of root cause shows tool wear on the roughing drill prior to final boring bar, qualification of the hole. There is no tool management system on this machine due to its age and lack of technology. Tool wear is usually detected by the operators checking the finish on the product as it comes off the machine. These parts have a two-part boring operation that utilizes a rough and finish process therefore masking the wearing drill. Another large factor for this particular machine would be the small working envelope that this machine has. It is at least 50% smaller than most CNC machines out on the floor. This causes a quicker increase in temperature within this machine, tripping the sensor, causing the fire suppression to activate. This scenario may not have activated the fire suppression in a larger machine causing both boring tools to break and significant surface finish that is easy for an operator to detect. 06/10/2009 3;30 Smoke OPT Two vacuum pumps seized causing two fuses to blow out a.m. LT2 Panel in the LT2 panel setting the fire suppression off. 08/24/2009 10:15 Heat TIC Cell E-16 Approximately 10:15 a.m. today the E-16 in the TIC cell a.m. overheated setting off the fire suppression. A drill snapped and made connection with a carbide end mill generating a massive amount of heat. Employees evacuated, the Fire Department arrived assessed the situation and gave the "all clear" allowing employees to re-enter the facility. 2/16/2010 7:10 Fire Burr Approximately 7:00 a.m. a small fire broke out in the a.m. Cell Hydromat Hydromat. The spindle was started and then the 'cycle start" button was hit to begin machining, operator quickly realized that the coolant was not on; when the coolant was turned on it hit the work piece and ignited. The suppression system immediately fired and extinguished the fire without injury to employees or damage to the machine. 3/11/2010 4:30 Fire BIGI Cell About 4:30 a.m. there was a fire at weld station #1. The a.m. Welding Station employee had just changed the acetylene bottle, and #1 there was a leak where the hose was reconnected. The leak ignited when it reached the pilot light sending out a flame. The fire was put out immediately and an investigation was conducted at 6:00 a.m. and revealed the hose had been split. Facilities replaced the hose and regulator for this station and inspected the hoses at station # 2. There were no injuries during this incident. Page 2 Mansfield Facility —Appendix D �® r1it&t ephew July 2017 Emergency Record Log 4/10/2010 1:10 Fire TIC Cell At 1:08 p.m, there was a small fire in the cavity of the p.m. Tsugami Tsugami due to the lack of coolant. No employees were injured and there was no damage to the machine or facility. The employees responded appropriately by evacuating immediately, taking attendance, communicating with emergency officials and contacting the emergency coordinators. 7/10/2010 8:48 Fire HIP Cell At 8:48 a.m. there was a small fire in the cavity of a.m. Willemin #5 Willemin #5. Possible difference in measure in tooling, not enough oil flow. No employees were injured and there was no damage to the machine or facility. The employees responded appropriately by evacuating immediately, taking attendance, communicating with emergency officials and contacting the emergency coordinators. 11/18/2010 7:30 Fire TIC Cell At 7:30 a.m. the CO2 bottle that went off today in the E- a.m. E-16 16 in the TIC cell was the result of a broken tool. The operator was running a CannuFlex Screw P/N 345553 batch number 50355856 when the front .052 drill broke off inside the screw being made. The 3/16 end mill came up and started milling the tip of the screw and came in contact with the broken drill and started to burn the end mill causing a large amount of smoke. The machine coolant was working properly at the time. 7/27/2011 6:30 Fire BIGI At approximately 6:30 this morning E-16 #1( Citizen a.m. E-16 swiss turning machine) in the BIGI cell had a small fire. Operator noticed a slight glow in the chip tray and opened both the front door and side door to see what was going on. Upon opening the second door a small fire started in both the front door and the side door of the machine. The operator called for assistance and Team Lead came to his aid with a hand held fire extinguisher putting out both fires. FAST arrived on site to inspect the fire suppression system. Slightly worn insert cutter — Tooling had shown no wear on previous cut parts but must have worn on this particular part in the machine. Low coolant — Coolant level was checked 10 days prior on the PM card but was slightly below the low level line introduction of air. 12/13/2012 1:50 Fire BIGI There was a small fire in the E16 in TIC cell at p.m. E-16 approximately 1:50 p.m. today. A Technician from Citizen-Cincom was grinding a door panel when a spark landed inside the machine; the machine was open with the panels removed. The fire was in the oil at the base of the machine; the S&N Operator grabbed the Type D dry powder extinguisher and put the fire out immediately. The technician stated the fire was very small (an inch or two high) and lasted about 10 seconds. There is no damage to the machine; however the dry powder did leave a bit of a mess. Peter is going to have the machine cleaned tomorrow. The Technician is aware of our safety rules and stated that he and his company have signed our Contractor Page 3 Mansfield Facility —Appendix D RsWth nopft w July 2017 Emergency Record Log Control documents. 2/20/2013 1:45 Smoke TIC At approximately 1:45 pm tool broke on E16 smoke no p.m. E-16 fire, fire suppression discharged and alarms went off. Everyone evacuated and fire department arrived. 4/18/2013 5:50 Fire TIC Approximately 5:50 a.m. employee (3rd shift— Machinist a.m. Hand Finishing III) was working at his finishing station located in the Station Titanium Implant Cell (TIC), hand finishing Titanium screws. Employee noticed smoke and a flame coming out of the local exhaust ventilation collection tube at the back of the grinder. Employee notified his supervisor, (3 d shift Production Supervisor), and then proceeded to grab a CO2 fire extinguisher from the main hallway nearby the tumblers in the TIC cell. Employee discharged the extinguisher at the finishing grinder and ventilation collection tube. The dust collector flashed causing the doors to blow open. By this time, the Supervisor, had arrived in the area and powered down the dust collector, then proceeded to a fire alarm. Employee grabbed a second fire extinguisher (an ABC -type from the Model Shop entrance) and discharged it at the dust collector. At the same time, John Engly (3rd shift — Machinist III working in the nearby Endo -button cell) grabbed an ABC - type extinguisher from his cell and discharged it at the dust collector as well. With the alarm engaged, the Supervisor returned to the cell and instructed both employees to exit the building. The Mansfield Police Department were the first to arrive on -site, entered the building, and it was observed that the fire had 'jumped' to the hand finishing station work surface where shop towels ignited. The fire began to grow out of control, and the overhead sprinkler engaged. The building was evacuated in accordance with emergency evacuation procedures. No employees were injured and all were accounted for. 8/5/15 5:55 Fire TMU BIGI At approximately 5:55 p.m. on 8/5/15 the fire p.m. suppression on the TMU discharged due to a fire sparked within the envelope of the machine. The building fire alarms went off and all the employees evacuated safely. 9/5/15 9:45 Fire TMU BIGI At approximately 9:45 p.m. on 9/5/15. The fire p.m. suppression on the TMU went off due to a fire sparked within the envelope of the machine. The building fire alarms went off and all the employees evacuated. Page 4 Mansfield Facility —Appendix D smith nephew July 2017 Emergency Record Log 3/16/2015 4:00 Smoke Electrical Room At 4:00 p.m. today the fire alarms went off. All p.m. Popcorn employees evacuated safety and were accounted for. The fire panel noted the trouble was on the 2"d floor. Before the fire department arrived I was told someone was making popcorn; The fire fighter and I made our way to the 2"a floor. We checked the cafeteria and all was good. I showed him the way to the electrical room and there it was and found the popcorn machine. Prior to the alarms going off, an employee from the Activities Committee was attempting to make green popcorn in the popper in the electrical room. The electrical room is equipped with heat sensors. The popper has been removed fiorn the electrical room, placed in the cafeteria and I have applied Lockout Tagout pending fo ther investigation 3/26/15 10:30 Faulty Sensor EDM #16 At approximately 10:30 this everting for a reason p.m. unknown at this time EDM machine #16 discharged its suppression system and triggered the alarm, no flames were observed and a heat source is undetermined at this point. Fire dept. arrived and cleared the alarm and we were back in the building at 10:50PM. Ted has spoken to the operator to try and determine what caused the discharge. We have powered down the equipment and I have asked Dale to lock it out. 7/14/16 4:00 Fire M20 Shaft At approximately 4:00 p.m. on 7/14/16 smoke p.m. started to pour out of the M20 in the Shaft cell. The fire suppression system did actuate, however, the CO2 did not discharge, An employee within the area hit the E-stop on the machine as he was evacuated the area. Alf the employees evacuated safely and orderly. The fire department arrived accessed the machine and silenced the fire alarms. The fire department brought industrial fans into the building to clear the smoke; this took about 30 minutes. Once the smoke was cleared the employees were allowed Page 5 Mansfield Facility —Appendix D Q lAhnephew July 2017 Emergency Record Log back into the building and LOTO was applied to the M20. 1/14/17 12:55 Fire TMU BIGI At approximately 12:55 a.m. on Wan2017. The fire a.m. suppression on the TMU went off due to a fire sparked within the envelope of the machine. The building fire alarms went off and all the employees evacuated. 7/17/17 8:45 Fire M420 TIC On Mut17 there was a fire in the Citizen M420V at a.m. 8:46 a.m. The fire suppressant discharged and the machine shut down. Employees evacuated safely, the Mansfield Fire Department (MFD) arrived in 5 minutes. After evaluating the situation the MFD brought in fans to clear the smoke. Once the smoke cleared they allowed the employees to re- enter the facility. Too( change frequency for the thread whirling inserts are not a current requirement but rather suggested. There is a setup sheet for the job with a notation to check inserts after 250 pieces. The parts that were being cut looked useable. Being a newer process the wear patterns are much different than we are used to seeing on our previous single point titanium threading inserts. Page 6 APPEADIX E Outside Assembly Area & Evacuation Route Maps FORBES BOULEVARD FRONT OF BUILDING REAR OF BUILDING 11111111111 IIIIIIIIL.O\��i ��IIIIIIIW' � 10, smith epeew Locations and Capabilities of Fire Extinguishers Mansfield Facility —Appendix F srriathUephew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 1. X Dry Chemical X A Lobby CO2 X B Halon X C AFFF D Other: 2. X Dry Chemical X A Manufacturing Support Copy Area (Outside of G. Munroe's office) CO2 X B Halon X C AFFF D Other: 3. X Dry Chemical X A Old Model Shop (next to exit sign) COZ X B Halon X C AFFF D Other: 4. X Dry Chemical CO2 X X A B Shaft Cell (First Floor next to double -door vestibule) Halon X C AFFF D Other: 5. X Dry Chemical X A Polymer Lab CO2 X B Halon X C AFFF D Other: 6. X Dry Chemical X A Outside of Toohnakers Shop CO2 X B Halon X C AFFF D Other: 7. X Dry Chemical X A Open Room near East Exit CO2 X B Halon X C AFFF D Other: Page 1 of 7 Mansfield Facility —Appendix F stAtWephew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 8. Dry Chemical A By Column TIC Cell CO, B Halon C AFFF D X Other: Super Dry Powder 9. Dry Chemical A Main Computer room —inside door CO2 B Halon X C AFFF D X Other: Clean Agent 10. X Dry Chemical X A QC Lab — By Back Door CO, X B Halon X C AFFF D Other: it. X Dry Chemical X A Hand Finishing area on wall next to Electro Polish CO, X B Halon X C AFFF D Other: 12. Dry Chemical A Telephone Closet (hrside Door) CO2 X B Halon X C AFFF D X Other: Clean Agent 13. X Dry Chemical X A Main Corridor — By Burr Cell CO, X B Halon X C AFFF D Other: 14. Dry Chemical A Cafd Kitchen Area CO2 X B Halon X C AFFF D X Other: Clean Agent Page 2 of 7 Mansfield Facility —Appendix F srfaith llephew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 15. X Dry Chemical X A Cafd Prep area CO2 X B Halon X C AFFF D Other: 16. Dry Chemical A CEII — Right side CO2 X B Halon X C AFFF D X Other: Clean Agent 17. Dry Chemical A CEII — Left side CO2 X B Halon X C AFFF D X Other: Clean Agent 18. X Dry Chemical X A By First Aid Kit CO2 X B Halon X C AFFF D Other: 19. X Dry Chemical X A Weld Room #1 Next to Curtain CO2 X B Halon X C AFFF D Other: 20. X Dry Chemical CO2 X X A B Inside of QC Implant Inspection area on wall Halon X C AFFF D Other: 21. Dry Chemical A Electric Room Behind CE II (Next To Door) X CO2 X B Halon X C AFFF D Other: Page 3 of 7 Mansfield Facility —Appendix F alnitil nphew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 22. X Dry Chemical X A Main Electric Room (Machining Area) COZ X B Halon X C AFFF D Other: 21 X Dry Chemical X A Sprinkler Valve Room COZ X B Halon X C AFFF D Other: 24. X Dry Chemical X A Outside Compressor Room CO2 X B Halon X C AFFF D Other: 25. Dry Chemical A Chip Spinning Room COz B Halon C AFFF X D X Other: Super Dry Powder 26. Dry Chemical A CEI Molding Room CO2 X B Halon X C AFFF D X Other: Clean Agent 27. X Dry Chemical X A CNC Turning Machining Area on Building column CO2 X B Halon X C AFFF X D Other: 28, X Dry Chemical X A Machine Shop by RAIII (on building column) CO2 X g Halon X C AFFF D Other: Page 4 of 7 Mansfield Facility —Appendix F smith nephew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 29. X Dry Chemical X A Outside HAZMAT Oil Storage Room CO2 X B Halon X C AFFF D Other: 30. X Dry Chemical X A Wall nest to Shipping & Receiving COZ X B Halon X C AFFF D Other: 31. X Dry Chemical X A Main corridor wall next to first aid cabinet COz X B Halon X C AFFF D Other: 32. X Dry Chemical X A Wall across from Berkshire Conference Room COZ X B Halon X C AFFF D Other: 33. X Dry Chemical X A Cafe next to vending machines (2" Floor) CO2 X B Halon X C AFFF D Other: 34. X Dry Chemical X A Wall next to Back stars — 2" Floor) CO2 X B Halon X C AFFF D Other: 35. X Dry Chemical X A Mezzanine Office — By Doors CO2 X B Halon X C AFFF D Other: Page S of 7 m,1Sflaila Mansfield Facility —Appendix F May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 36. X Dry Chemical X A Implants Mezzanine - By Door COz X B Halon X C AFFF D Other: 37. X Dry Chemical X A 5 Extra Extinguishers in facilities office COz X B Halon X C AFFF D 38. X Dry Chemical X A EDM Cell on Column COz X B Halon X C AFFF D Other: 39. X Dry Chemical X A Sterile Pack Outer Boxing on Column CO, X B Halon X C AFFF D Other: 40. Dry Chemical A CEIII on Column CO2 X B Halon X C AFFF D X Other: Clean Agent 41. Dry Chemical A CEIII on wall next to FFS machine COZ X B Halon X C AFFF D X Other: Clean Agent 42. X Dry Chemical X A Outside Model Shop Door (Hall) CO2 X B Halon X C AFFF D Other: Page 6 of 7 Mansfield Facility —Appendix F sadthftephew May 2017 Fire Extinguisher Types and Locations Fire Ext. No. Type Class Location 43. Dry Chemical A TIC Hand Finishing COy B Halon C AFFF D X Other: Super Dry Powder 44. X Dry Chemical X A Main Hall by FAB Cell COZ X B Halon X C AFFF D Other: Super Dry Powder Page 7 of 7 APPENDIX G Locations of C'Oz Fire Suppression Systems Mansfield Facility— Appendix G September 2017 Location of Fire Suppression Systems � % smith nephew Location/Cell Machine Suppression Comments/Asset # BIGI M32 FM200 Firetrace BIGI Eldorado Gun Drill FM200 Firetrace BIGI E16 -3 CO2 BURR Rolomatic #1 CO2 BURR Rolomatic #2 CO2 BURR Rolomatic #3 CO2 BURR Rolomatic #4 CO2 BURR Rolomatic #5 CO2 BURR L-20 #3 CO2 BURR Hydromat CO2 EDM RAM EDM #8 FM200 Firetrace FAB ECTRA FM200 Firetrace EDM RAM EDM #12 FM200 Firetrace EDM RAM EDM #13 FM200 Firetrace EDM RAM EDM #16 FM200 Firetrace EDM RAM EDM #18 FM200 Firetrace HIP ROBO DRILL FM200 Firetrace HIP Willieman #1 CO2 HIP Willieman #3 CO2 HIP Willieman #4 CO2 Page 1 of 3 Mansfield FacilitY — APP endixG '6 smithUephew September 2017 Location of Fire Suppression Systems HIP Willieman #5 CO2 Location/Cell Machine Suppression Comments HIP Willieman #8 CO2 HIP Willieman #9 CO2 HIP Willieman #10 FM200 Firetrace HIP Matsuura #1 CO2 Three 100 lb bottles for both #1 & #2 HIP Matsuura #2 CO2 Three 100 lb bottles for both #1 & #2 HIP Tsugami TMU CO2 HIP E32 -2 CO2 HIP E32 -1 CO2 Hand Finishing Electropolish Coe 2 Bottles Shaft M$20 FM200 Firetrace Shaft C-16 CO2 Shaft L-2 ##1 CO2 Shaft M-16 CO2 Shaft E-32 #3 CO2 Shaft E32-1 CO2 Shaft L20X CO2 Shaft Tsugami BH20-3 CO2 Shaft Tsugami BH20 - 2 CO2 TIC Citizen M4 20 FM200 Firetrace Page 2 of 3 Mansfield Facility — Appendix G September 2017 Location of Fire Suppression Systems N sc iftft �r , he TIC Tsugami BH2O CO2 TIC L-20 #2 CO2 Location/Cell Machine Suppression Comments TIC L-20 CO2 Q1322 TIC M-20 CO2 5248 TIC E-16 CO2 803 Welding Station #1 Above Welder CO2 Welding Station #2 Above Welder CO2 Cafeteria Cafeteria Grills Ansul Dry Computer Room Halon Rollomatic DPW FM200 Firetrace Page 3 of 3 10 Locations of Spill Cotth•ol Equipment IncItiditig PPE MansfieldFacilitY— Appendix H smi t nephew May 2017 Locations of Spill Control Equipment Including Personal Protective Equipment (PPE) Location Tye Spill Control Equipment PP) Hazardous Waste/Oil Cabinet & Absorbent socks, pads, Rubber gloves, boots, Storage Room Overpack granular material and and Tyvek suits Container plastic disposal bags. Electropolish 30-Gallon Absorbent socks, pads, Rubber gloves, glove Bucket sodium bicarbonate extensions (gauntlets), (neutralizer) face shield, boots, and Tyvek suits. Polymer Lab Cabinet Treatment Kit with agents Rubber gloves, safety and PPE glasses/goggles and booties Quality Test Lab Cabinet Treatment Kit with agents Rubber gloves, safety and PPE glasses/goggles and booties TOC Box Absorbent socks, pads Rubber gloves, safety glasses/goggles and booties EDM Box Absorbent socks, pads Rubber gloves, safety glasses/goggles and booties TIC Box Absorbent socks, pads Rubber gloves, safety glasses/goggles and booties and booties BURR Box Absorbent socks, pads Rubber gloves, safety glasses/goggles and booties SHAFT Box Absorbent socks, pads Rubber gloves, safety glasses/goggles and booties Service Alley/Alcohol Box Absorbent socks, pads Rubber gloves, safety Recycler glasses/goggles and booties