HomeMy WebLinkAboutPark St. #15 - Oil - 3/11/2008Aug. 10. 2007 10:59AM MASS DEP No.9889 P. 2/7
COMMONWEALTH OF MASSACHUSETTS13
EXECUTIVE OFFICE OF ENERGY & ENVIRO IRS J %
DEPARTMENT OF ENVIRONMENTAL PR �i+`�j
SOUTHEAST REGIONAL OFFICE 1��o jj
20 RIVERSIDE DRIVE, LAKEVILLE, MA 02347 508
DEVAL L_ PATRICK IAN A, BOWLES
Governor Secretary
TIMOTHY P. MURRAY ARLEEN O'DONNELL
Lieutenant Governor Commissioner
August 8, 2007 �
Michael Forbes, Executive Director LS P C Ll T r,
Mansfield Housing Authority A U u 1 0 2' 0; E r
22 Bicentennial Court
Mansfield, Massachusetts 02048-1558
RE: NOTICE OF AUDIT FINDINGS/
NOTICE OF NONCOMPLL4,NCE
MANSFIELD
Mansfield Housing Authority
15 Park Street
`-RTN:4-178§4
NON-SE-07-3A-017
Dear Mr. Forbes:
On April 3, 2007, The Mansfield Housing Authority (hereafter referred to as you/your) were
notified that the Massachusetts Department of Environmental Protection (the Department or
MassDEP) had begun to audit response actions conducted to address the release of oil and/or
hazardous material at the location referenced above. This Notice informs you of the results of the
MassDEP's audit.
In particular, the audit focused on the Immediate Response Action Completion Report and Class
A-1 Response Action Outcome Statement (RAO). A three-story Senior Citizen apartment
complex occupies the Site. A hydraulic oil leak from a damaged underground feed pipe to the
elevator was discovered after the elevator stopped working properly. Approximately thirty (30) to
fifty (50) gallons reportedly leaked over an extended period of time from the corroded pipe under
the slab foundation. Contaminated soil was treated with an in -situ biological system that relied on
groundwater circulation and nutrient enhancement. Mass))EP received the RAO document on July
18, 2005. On April 11, 2007, Lynne Doty of the MassDEP Southeast Regional Office conducted an
audit inspection, and discussed preliminary comprehensive findings at the Site with you and Ralph
Penney, LSP,
Thi, informadnn i, avaliable In alternate format Caa Donald Id. Gomm, ADA Cooadinatorat 617-356.1057. TDD Semlce. 1•110&299-220.
DEP on the World Wide Web; http:/MAwi.tnesa,gm/dep
0 Printed on R6gdbd Pdpet
Aug, 10. 2007 10:59AM MASS DEP
Page 2
Mansfield RTN 4-17894
VIOLATIONS IDENTIFIED
No.9889 P. 3/7
Notice of Audit Findings and Notice of Noncompliance
The Department has determined that response actions. were not performed in compliance with the
requirements of the Massachusetts Contingency Plan (MCP), The enclosed Notice of
Noncompliance lists the violations and actions that are required to achieve compliance.
Specifically, the Notice of Noncompliance contains: (1) the requirements violated, (2) the date
and place that the Department asserts the requirement was violated, (3) either the specific actions
which must be taken in order to return to compliance or direction to submit a written proposal
describing how and when you plan to return to compliance and (4) the deadline for taking such
actions or submitting such a proposal.
LICENSED SITE PROFESSIONAL (LSP)
A copy of this notice has been sent to Ralph P. Penney, LSP 47755, the LSP-of-Record for the
Disposal site. Iloweder, you, not your LSP, are responsible for correction of any identified
violations.
LIMITATIONS
MassDEP's findings were based upon the certainty of the information reviewed during the audit.
These findings do not: (1) apply to actions or other aspects of the site that were not reviewed in the
audit, (2) preclude. fitture audits of past, current, or future actions at the site, (3) in any way
constitute a release from any liability, obligation, action or penallty under M.G.L. c. 21E, 310 CMR
40.0000, or any other law, regulation, or requirement, or (4) limit the Department's authority to take
or arrange, or to require any Responsible Party or Potentially Responsible Party to perform, any
response action authorized by M.G.L. c. 21E which the Department deems necessary to protect
health, safety, public welfare, or the environment.
If you have any questions regarding this Notice, please contact Ms. Lynne Doty at (508) 946-2886.
Please reference the Release Tracking Number 4-17894 in any future correspondence to MassDEP
regarding the Site.
Sincerely,
Deborah A. Marshall, Chief
Audit Program
Bureau of Waste Site Cleanup
M/LD/rr
Audits?cdomad/Compmhensivet4-17894A.17894nmf j
CERTIFIED MAIL # 7002 2030 0006 4996 1948
Enclosure: Notice of Audit Findings and Noncompliance
Aug. 10. 2007 10:59AM MASS DEP No.9889 P. 4/7
Page 3 Notice of Audit Findings and Notice of Noncompliance
Mansfield RTN 4-17894
I'c: Fax: ( 508) 261-7498 and (508) 261-7425
Mansfield Board of Selectmen
Mansfield Health Department
Fax: (508) 261-1288
Ralph Penney, LSP
Penney Engineering, Inc.
125 High Street
Mansfield, Massachusetts 02048
ec: DEP-SERO
AT1N: Office of Regional Enforcement (2)
Data Entry: AUDCOM NAFNON, RAO ACTAUD
Aug. 10. 2007 10:59AM
MASS DEP No.9889 P. 5/7
Page 4
Mansfield RTN 4.17894
Notice of Audit Findings and Notice of Noncompliance
NON-SE-07-3A-017
RTN 4-17894
THIS IS AN IMPORTANT LEGAL NOTICE.
FAILURE TO RESPOND COULD RESULT IN SERIOUS LEGAL CONSEQUENCES.
NAME OF ENTITY IN NONCOMPLIANCE:
Michael Forbes, Executive Director
Mansfield Housing Authority (MIA)
22 Bicentennial Court
Mansfield, Massachusetts 02048-1558
LOCATION WHERE NONCOMPLIANCE OCCURRED OR WAS OBSERVED:
15 Park Street
Mansfield, Massachusetts 02048
DATE WHEN NONCOMPLIANCE OCCURRED OR WAS OBSERVED:
July 18, 2005 (Date that the "IRA Completion Report and RAO Statement" was received by the
Department)
DESCRIPTIONS OF REQUIREMENTS NOT COMPLIED WITH:
Except as provided by 310 CMR 40.0025, each person who is required by M.G.L. c. 21E, 310
CMR 40,0000 or any order or determination of the Department, to make one or more submittals
to the Department shall make each submittal by the deadline or within the time period imposed
within.
Several required documents were submitted to MassDEP from two to four months late. These
included the Phase I I Tier Classification, IRA Plan and subsequent IRA status reports.'
There is no corrective action required for this violation at this time. However, the violation may
be used to establish a pattern of noncompliance if future enforcement actions are pursued.
Aug.10. 2007 11;00AM MASS DIP No.9889 P. 6/7
Page 5 Notice of Audit Findings and Notice of Noncompliance
Mansfield RTN 4-11894
Vinlxfiinn of 910
�ti� and L41(hl (ClaeQ TT C�enerat Annlicatinn of Remedial
CAIR 4n nn4fi �
� -r-�-
AAnititivPs ann Rpglyjr m n S nr the Trratm nt of Sn��t C;rmmdwate>-
Any person performing response actions at a disposal Site pursuant to M.G.L. c,21E and 310
CUE 40.0000 may apply remedial additives to the ground surface or subsurface and/or
groundwater, provided such application, and any remedial additive by-product does not result in
concentrations that exceed the Massachusetts Ground Water Quality Standards established by
314 CUR 6.00, or the applicable groundwater or soil standards set forth in 310 CMR 40.0000, at
any point measured fifty (50) feet or more downgradient from the furthest downgradient point of
application, and;
Each person performing response actions at a disposal Site pursuant to M.G.L. c.21E and 310
CME 40.0000 that include the application of remedial additives shall: after each application of
remedial additives, monitor the groundwater hydraulically upgradient and downgradient, and
where practicable underlying the point of application of the remedial additives at regular
intervals not to exceed every three months thereafter to detect any migration of oil and/or
hazardous material, remedial additives and/or remedial additive by-products from the disposal
Site.
The groundwater immediately underlying the point of application of remedial additives at this
Site was monitored on a regular basis until contaminants were below background levels.
However, the requirement to monitor at hydraulically upgradient and downgradient locations was
not met and supported in the RAO either by technical justification or schematic drawings. As a
result of not presenting monitoring data for these locations, it was not possible to definitively
determine if the Groundwater Quality Standards were exceeded beyond fifty (50) feet from the
application point. In addition, since the location of the "domestic auxillary" wells were not
depicted on the Site Plan it could not be determined if any of these wells also required sampling.
v ARu dO n19�ro1a¢4 Technical Tnetificatinn
When forgoing any particular activity in accordance with 310 CMR 40,0193(1), the LSP shall
identify such activity, and shall set forth the basis for such technical justification in the pertinent
submittal.
The LSP failed to provide the technical justification to limit the assessment of the property with
respect to monitoring of groundwater.and soil as required for the application of Remedial
Additives. Although the treatment protocol employed likely resulted in the containment of
groundwater, during recirculation and soil treatment, there was no technical justification
provided for forgoing the required groundwater monitoring. The heavy application of nitrogen
containing lawn fertilizer, building configuration, extensive experience with similar system
design results, extent of contamination and contaminant fate and transport arguments presented
by the LSP during the audit field inspection were not provided in the RAO,
Virnafiinn nr +n. �'tR 4n 1nn4 (ClaQe� Performance Ctandardc for RPcnnnse Action
Outromes
Aug. 10. 2007 11:00AM MASS DEP No.9889 P. 7/7
Pace 8 Notice of Audit Findings and Notice of Noncompliance
Mansfield RTN 4-17894
The Response Action Outcome Statement shall be supported by assessments and evaluations
conducted pursuant to 310 CMR 40,0000 which are of sufficient scope, detail, and level of effort
to characterize the risk of harm to health, safety, public welfare and the environment posed by the
disposal Site, and demonstrate that all requirements of the applicable class of RAO have been
met.
The text of the RAO describes assessment activities but the plan scale chosen to depict the Site
was not sufficient to allow for verification of the vertical and horizontal extent of hydraulic oil
contamination, and its proximity to the treatment system. Additionally, the plan did not show the
location of the pipe that leaked and the sixteen (16) soil sampling points. Furthermore, without a
detailed design drawing of the treatment system, that shows it's proximity to the contamination
and soil samples collected at the Site, it is difficult to definitively verify the technical adequacy of
the bioremediation protocol. Furthermore, the Site plan depicted an extraction well that was
never installed and failed to show the location of the four irrigation wells that caused the Site
groundwater to be classified as GW-1.
ACTIONS TO BE TARN AND THE DEADLINE FOR TAKING SUCH ACTIONS:
Within sixty (60) days following receipt of this Notice you must submit a Post -Audit
Completion Statement (13WSC-111) prepared in accordance with 310 CMR 40,1170,
accompanied by either Option A or Option B below:
Option A Submit to MassDEP a revised RAO for the Site, if conditions that support an RAO
have been met, and include the missing information needed to verify that the full
extent of contamination has been addressed. This revised RAO shall be prepared in
full accordance with the provisions of the MCP and include all necessary technical
justifications, revised plan drawings and other pertinent information identified in the
violations listed above.
OR
Option B Retract the existing RAO Statement Opinion pursuant to 310 CMR 40.0500 and
continue response actions in accordance with 310 CMR 40.0000 can be achieved for
the Site.
A copy of the Post -Audit Completion Statement form (BWSCill) can be located on the
Department's web site at the following address:
+nr�m //waw mac¢ g /�/h��cc/file¢/forme/nclffnrmc/hwcc-111 nrlf.
If the required actions are not completed by the deadline specified, an administrative penalty may
be assessed for every day after the date of this Notice that the noncompliance occurs or continues.
The Department reserves its rights to exercise the full extent of its legal authority in order to
obtain full compliance with all applicable requirements, including, but not limited to, criminal
prosecution, civil action including court -imposed civil penalties, or administrative action,
including administrative penalties imposed by the Department.
Aug. 10. 2007 10:59AM MASS DEP No.9889 P. 1/7
DEVAL I, PATRICK
Governor
TIMOTHY P. MURRAY
Lieutenant Govemor
COMMONWEALTH OF MASSACHUSETTS .
EXECUTIVE 0mcE OF ENERGY & ENVIRONMENTAL AFFAIRS
DEPARTMENT OF ENVIRONMENTAL PROTECTION
SOUTHEAST REGIONAL OFFICE
20 RIVERSIDE DRIVE, LAKEVILLE, MA 02347 508-946-2700
FAX: (508) 947-6557
ARISEN UDONNELL
00=i8sionea
To F.ax From: Roslyn Relmao Phone: (508) W-2883
S (fig) 2,6<
Date, 6 Q
pagesn. plus this cover page
Comments: Please find attached letter(s);c'iS
written by: - tlx�
Y-6p,f/���
Mite Information Is available in alteraolefmmae CaDDonald M.Game; ADA Coordinator at 6t7-M&I857. TOD 8eM=— I -ND MM07.
DEPonthe WoddWlda Web: hdpAunw,meeanovldep
() Minted an Recycled paper
PENNEY ENGINI
Environmental Engineers & Scientists
July 18, 2005
Mr. John 0. D' Agostino, Town Manager
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508) 261-7370
RE, 15 Park Street, Mansfield
RTN 4-17894
Dear Messrs. D' Agostino and Leite:
�T, INC z 'g
v
ILI
y /
Mr. Scott Leite, Health Agent
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508) 261-7366
On behalf of the Mansfield Housing Authority and in accordance with the public
involvement requirements of the Massachusetts Contingency Plan, 310 CMR 40.1400,
Penney Engineering, Inc is hereby providing written notification to your offices of the
availability of our July 2005 Immediate Response Action (IRA) Completion Report and
Response Action Outcome (RAO) Statement for the remediation of a release of
approximately 50-gallons of hydraulic oil at its Park Court Building located at 15 Park
Street. The oil leaked from an underground pipe for the piston -type elevator at the
building. We installed a biological treatment system and remediated the oil
contaminants to background concentrations. No imminent hazards to the health and
welfare of the public have been identified in the area of the release. A condition of No
Significant Risk has been achieved at the site.
Local officials may obtain copies of the Immediate Response Action Completion Report
and Response Action Outcome Statement by contacting the DEP Southeast Regional
Office at (508) 946-2714 and referring to Release Tracking Number: 4-17894.
Yours truly,
04114W e. ! �
Ralph P. Penney, PE, LSP
President
cc: Mansfield Housing Authority
125 High Street, Mansfield, MA 02048
web: www.PenneyEng.com
(508) 261-1288 o FAX (508) 261-1208
email: sales@PenneyEng.com
PENNEY ENGINEERING, INC
Environmental Engineers & Scientists
September 24, 2004
Mr. John O. D' Agostino, Town Manager
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7370
RE: 15 Park Street, Mansfield
RTN: 4-17894
Dear Messrs. D' Agostino and Leite:
Mr. Scott Leite, Health Agent
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7366
On behalf of the Mansfield Housing Authority and in accordance with the public
involvement requirements of the Massachusetts Contingency Plan, 310 CMR 40,1400,
Penney Engineering, Inc is hereby providing written notification to your offices of the
availability of a combined Phase I Initial Site Assessment Report and Tier Classification
Submittal for a release of approximately 50-gallons of hydraulic oil at its Park Court
Building located at 15 Park Street. The oil leaked from an underground pipe for the
piston -type elevator at the building. We have installed a biological treatment system to
remediate the oil. No imminent hazards to the health and welfare of the public have
been identified in the area of the release.
Local officials may obtain copies of the combined Phase I Initial Site Investigation
Report and Tier Classification Submittal by contacting the DEP Southeast Regional
Office at (508) 946-2714 and referring to Release Tracking Number: 4-17894.
Yours truly,
Ralph P. Penney, PE, LSP
President
cc: Mansfield Housing Authority
esse Krawiec
Staff Scientist
125 High Street, Mansfield, MA 02048 (508) 261-1288 • FAX (508) 261-1208
web: www.PenneyEng.com • email: sales@PenneyEng.com
PENNEY ENGINEERING INC
Environmental Engineers & Scientists
September 27, 2004
Mr. John O. D'Agostino, Town Manager
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7370
RE: 15 Park Street, Mansfield
RTN: 4-17894
Dear Messrs. D'Agostino and Leite:
Mr. Scott Leite, Health Agent
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7366
On behalf of the Mansfield Housing Authority and in accordance with the public
involvement requirements of the Massachusetts Contingency Plan (310 CMR 40.1400),
Penney Engineering, Inc is hereby providing written notification to your offices that the
enclosed legal notice shall be published in the Mansfield News on Friday, October 1,
2004. The property located at 15 Park Street has been recommended for classification
as a Tier II disposal site. No imminent hazards to the health and welfare of the public
have been identified at the property.
Your offices were previously notified of the availability of the Phase I Initial Site
Investigation Report and Tier Classification Submittal by our September 24, 2004 letter.
Yours truly,
-4Z
Ralph P. Penney, PE, LSP 2Jess Krawiec
President Staff Scientist
Enclosure
cc: Mansfield Housing Authority
125 High Street, Mansfield, MA 02048 (508) 261-1288 • FAX (508) 261-1208
web: www.PenneyEng.com email: sales@PenneyEng.com
NOTICE OF AN INITIAL SITE INVESTIGATION AND
TIER it CLASSIFICATION
MANSFIELD HOUSING AUTHORITY
PARK COURT BUILDING
15 PARK STREET, MANSFIELD, MA
RELEASE TRACKING NUMBER: 4-17894
Pursuant to the Massachusetts Contingency Plan (310 CMR 40.0480), an Initial
Site Investigation has been performed at the above referenced location. A
release of oil and/or hazardous materials has occurred at this location which is a
disposal site (defined by MGL c. 21 E, Section 2). This site has been classified as
Tier II, pursuant to 310 CMR 40.0500. Response actions at this site will be
conducted by Mansfield Housing Authority who has employed Ralph P. Penney,
LSP, to manage response actions in accordance with the Massachusetts
Contingency Plan (310 CMR 40.0000).
MGL c. 21 E and the Massachusetts Contingency Plan provide additional
opportunities for public notice of and involvement in decisions regarding
response actions at disposal sites: 1) The Chief Municipal Official and Board of
Health of the community in which the site is located will be notified of major
milestones and events, pursuant to 310 CMR 40.1403; and 2) Upon receipt of a
petition from ten or more residents of the municipality in which the disposal site is
located, or of a municipality potentially affected by a disposal site, a plan for
involving the public in decisions regarding response actions at the site will be
prepared and implemented, pursuant to 310 CMR 40.1405.
To obtain more information on this disposal site and the opportunities for public
involvement during its remediation, please contact Ralph P. Penney, LSP,
Penney Engineering, Inc, 125 High Street, Mansfield, MA 02048 at (508) 261-
1288.
Apr. 5, 2007 6:41PM MASS DEP No.5880, P. 2/5 CV'
COMMONWEALTH OF M.A,SSACHUSETTS
EXECITPIVE OFFICE OF ENVIRONMENTAL
DEPARTMENT OF ENVIRONMENTAL PRO[ll'<IB�j
SOUT14EAST REGIONAL OFFICE ��JJ�� 11
20 RIVERSIDE DRIVE, LAKEVILLE, MA 02347 508.9
DEVAL L. PATRICK
Governor
TIMOTHY P_ MURRAY
Lieutenant Governor
Michael Forbes, Executive Director
Mansfield Housing Authority
22 Bicentennial Court
Mansfield, .Massachusetts 02048-1558
Dear Mr. Forbes:
�rc (� � I1 �� l5
Av 1r s 4, N07
April 3,
RE: MANSFIELD -- BWSC/AP
RTN: 4-17894
Mansfield Housing Authority
15 Park Street
Response Action"Outcome
NOTICE OF AUDIT
REQUEST FOR SITE INSPECTION
IAN A. BOWLES
Secretary
ARLEEN O'DONNELL
Commissioner
The Massachusetts Department of Environmental Protection's Bureau of Waste Site Cleanup
(the Department or MassDEP) has selected the above referenced site for an audit. MassDEP
audits response actions conducted without MassDEP oversight at oil and/or hazardous material
disposal sites, in order to ensure that these actions meet the requirements of Massachusetts laws
and regulations, including Massachusetts General Law Chapter 21E and the Massachusetts
Contingency Plan (MCP), 310 CMR 40.0000.
The enclosed Audit Fact Sheet (Attachment A) outlines the audit process and provides the
citations in the MCP that relate to the audit process. Audit staff from the Southeast Regional
Office will primarily focus on the "Immediate Response Action (IRA) Completion Report and
Response Action Outcome (RAO) Statement", prepared by Penney Engineering, Inc. and
received by MassDEP on July 18, 2005 for this audit evaluation. In addition, the following
documents, prepared on your behalf by Penney Engineering, Inc., are available in MassDEP
records for the site and may be evaluated during this audit:
Immediate Response Action Plan dated November, 2003
Phase I Initial Site Investigation Report and Tier Classification dated September, 2004
Immediate Response Action Status Report dated October, 2004
Immediate Response Action Status Report dated January, 2005
IRA Completion Report and RAO Statement dated July, 2005
Thla lntormadan D avadaale In alternate format. Caa Donald M. Games. ADA Coordinatorat 617 SSb1sS7. TDD Servlee. 1.M298.2287,
DEPontheWorld Wlde Web: hllp:/Avxnv.maas.gov/dap
0 Pdntad on R"ded Paper
Apr. 5. 2007 6:41PM MASS DEP No.5880 P. 3/5
MANSFIELD, RTN 4.17894 2 Notice of Audit
MassDEP's evaluation of the site's compliance status will be based primarily on the
information in these documents. If you are aware of additional, existing documentation relevant
to the response actions being audited at the site, please submit it to MassDEP within seven (7)
days of your receipt of this Notice. Any submittal made in response to this Notice must contain
the attached Certification of Submittal, per 310 CMR 40.0009 (Attachment B).
Request For Site Inspection
MassDEP requests an appointment to inspect the site on Wednesday, April 115 2007 at 2:00
PM. Ms. Lynne Doty will conduct the inspection. You or a representative with access to the site,
and the Licensed Site Professional (LSP) familiar with the site, are requested to attend. The
purpose of the inspection will be to evaluate the site conditions in relation to the information
received by MassDEP, and to discuss issues identified during MassDEP's record review.
Preliminary audit findings based on the MassDEP's file review may also be discussed during
the site inspection. Please call Lynne Doty within five (5) days of receipt of this Notice at (508)
946-2886 to either confirm the appointment or to arrange an alternative date or time.
Audit Results
After the site inspection, MassDEP will evaluate whether the actions taken at the site are in
compliance with applicable regulations and meet the performance standards needed to protect
health, public welfare, safety, and the environment. The determination of compliance will be
based on the work performed as of the date the submittal was received by MassDEP. You will
receive a Notice of Audit Findings (N OAF) summarizing the results of the audit.
If the MassDEP finds that response actions were not conducted in compliance with the MCP,
you will be notified of the actions needed to return to compliance. The Department may set
deadlines that you will be expected to meet to correct any violations, or the Department may
pursue higher -level enforcement.
Please call Lynne Doty at (508) 946-2886 if you have any questions about this Notice.
MassDEP appreciates your anticipated cooperation in this matter.
^Sincerely, —0 `s
Deborah A. Marshall, Chief
Audit Program
M/LD/
Audit&T&Ormed/Comprehenelve/4-17994NOA
Apr. 5. 2007 6.42PM MASS DEP No.5880 P. 4/5
MANSFIELD, RT'N 4.17894
Attachments: A. Audit Fact Sheet
B. Certification of Submittal
fc: Mansfield Board of Selectmen/Chief Municipal Officer
Mansfield Board of Health/Health Department
Fax: (508) 261-7498 and (508) 261-7425
Ralph P. Penney, PE, LSP
Penney Engineering, Inc.
125 High Street
Mansfield, Massachusetts 02048
Fax: (508) 261-1288
ec: DEP-SERO
Data Entry: AUDCOM NOA
Notice of Audit
Apr, 5. 2007 6:42PM MASS DEP NO.5880 P. 5/5
04/05/2007 THU 17:44 FAX
' 001
*** FAX RX REPORT ***
RECEPTION OK
JOB NO.
5439
DESTINATION ADDRESS
5089476557
PSWD/SUBADDRESS
DESTINATION ID
ST. TIME
04/05 17.44
USAGE T
00,38
PGS.
5
RESULT
OK
Apr, 5. 2007 6:41PM MASS DEP
No.5880 P. 1/5
.DEVALI. pATRIcK
Governor
TIMOTHY P. MURRAY
Lieutenant Governor
COMMONWEALTH OF MASSACFWSETTS_
EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS
DEPARTMENT OF ENVIRONMENTAL PROTECTION
SOUTHEAST REGIONAL OFFICE
20 RIVERSIDE DRIVE, LAKEVILLE, MA 02347 508-946-2700
FAX: (508) 94
AI>R 0 C
IAN A. BOWLS
Secretary
ARLEEN (YDONNELL
GD)DUlieaioner
To Fax #(s)i From. Roslyn Relmao Phone: (508) M 28e3
1�US Cs6g 2-
Comments: Please find attached letter(s):
written by:
Pages: rx plus this cover page
4 o r�
NOi4/tP, F 5 T
/ I6-�LJ*9
I
F
:
7BIs Informadon D 27a9361e iA 610or6ate f0rmat. Cag Donald At Comet, ADA Coordinator at 617-M-11157, T'DD 1$00.29&2207,
DEP od the Wodd Won Web: httplAwiw.mass,gov/dep .
0 Pdnledon Req rJed Paper
Environmental Engineers & Scientists
March 11, 2008
Mr. John O. D'Agostino,
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7370
Town Manager
RE: 15 Park Street, Mansfield i
RTN: 4-_17&94__
Dear Messrs. D'Agostino and Leite:
MAR 1 3 20Q8
I Ii
Mr. ScotIi teite Health Agent -'
TOWN OF MANSFIELD
Six Park Row
Mansfield, MA 02048
(508)261-7366
On behalf of the Mansfield Housing Authority and in accordance with the public
involvement requirements of the Massachusetts Contingency Plan, 310 CMR 40.1400,
Penney Engineering, Inc is hereby providing written notification to your offices of the
availability of our March 2008 Revised Immediate Response Action (IRA) Completion
Report and Response Action Outcome (RAO) Statement for the remediation of a
release of approximately 50-gallons of hydraulic oil at its Park Court Building located at
15 Park Street. The oil leaked from an underground pipe for the piston -type elevator at
the building. We installed a biological treatment system and remediated the oil
contaminants to background concentrations. No imminent hazards to the health and
welfare of the public have been identified in the area of the release. A condition of No
Significant Risk has been achieved at the site. Our July 2005 IRA Completion and RAO
Statement were revised to provide additional technical justification for our actions.
Local officials may obtain copies of the Revised Immediate Response Action
Completion Report and Response Action Outcome Statement by contacting the DEP
Southeast Regional Office at (508) 946-2714 and referring to Release Tracking
Number: 4-17894.
cc: Mansfield Housing Authority
125 High Street, Mansfield, MA 02048
(508) 261-1288 m FAX (508) 261-1208
mmil: sales@PenneyEng,corn
web: www.Pen neyFng.corn